Setting temperatures scales "°C - °F"(valid for revision 16v1 and higher)
Machine comes with temperature settings set to Celsius (°C) as a default. For revision "16v1" and higher of the control
board, operator can switch between degrees Celsius (°C) and Fahrenheit (°F) by following below procedure:
1. Make sure the machine is turned off; main switch (page.20 pos.F) in OFF position
2. While holding down
control board's screen shows
3. In order to return back to the degrees Celsius (°C), repeat what is in the previous step
Before switching the machine on, it should be cleaned properly as reported in the "Cleaning" paragraph.
Always comply with the provisions of the local authorities in charge regarding the cleaning of the machine.
Daily clean and sanitize the machine.
Before carrying out whatever operation, switch off the machine (page 20 pos. F) and unplug it.
Use a solution of cold water and sodium hypochlorite (bleach) with the following proportion: 10 grams (1/2 tea
spoon) for each liter of water. Rinse with warm water.
A greater quantity of bleach could damage the augers.
If the plastic parts are dishwashed, ensure the temperature is not higher than 60°C or 140°F, because they could be
damaged.
Do not use abrasive powder.
Cleaning is very important if you want the machine to last longer; it is therefore useful to periodically wash all parts in
contact with the product, using the following procedure:
Please see the pictures at pages 40-41 of this instruction manual:
- Use disposable gloves;
- Open the tap in order to empty the tank. Leftovers can be kept in the refrigerator in special tanks if allowed by the
local authorities in charge;
- Remove the cover, as illustrated in pic.1;
- In the event the cover has a key lock, use the key provided and remove the cover as shown in fig. 18, 19, 20, 21 and
22;
- Pour water in the tank and empty it again;
- Remove the tap from the tank as illustrated in pic.2-3-4-5;
- Remove the sleeve with star hole as illustrated in pic.6;
- Remove the hooks grips, if present;
- Open the groups as illustrated in pic.7 and lift the tank as in pic.8-9;
button on the front control board, turn the machine back ON. Release
TEMP. SET IN °F
TEMP. SET IN °C
Proper usage

Cleaning

Cleaning the tank
- 23 -
button, when