Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

General Instructions

Nozzle Installation:
Note: Nozzles should be installed
first.
If installing Rigid Gooseneck
1. Apply teflon tape or pipe joint
compound to threaded end of no.9.
2. Tighten no.9 firmly by hand into
no.2.
9
2
If installing Swivel Nozzle:
3. Insert no.9 or no.10 into no.2 and
rotate to front of sink.
4. Tighten no.16 firmly with a wrench.
9 or 10
11, 12,
14, 15
For swivel repair or replacement of
('o'-ring) no.15 and (sleeves) no.14:
5. Insert one no.14 onto no.11. Install
no.15 on no.11 and lubricate liberally
with provided no.17. Install second
no.14 onto no.11. (See Enlarged View)
Faucet Installation:
6. Shut off water supply and drain
lines. Drill (2) two holes, approxi-
mately 1-1/4" [3 cm] diameter in wall
with 8" [20 cm]centers, where you are
installing no.1.
7. Apply teflon tape or pipe joint
compound to water supply lines.
8. Connect no.2 to water supply lines
by attaching no.3 with eccentric
centers onto nipple supplied by
others and tighten no.3 against wall.
Make sure no.4 is in place. Nut
behind wall to be supplied by others.
Trim supply lines if necessary.
16
2
2
3
water supply line
9. Turn on water supply and check
for leaks.
4
11
14
15
Enlarged View
8"
[20cm]
wall
4
nut
(supplied by others)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

B-0231B-0232B-0330

Tabla de contenido