• You will not be able to select the desired type of hydromas-
sage and the display will continue to show "Waiting Position".
• The LED for the
key on the receiver flashes.
• Aim the remote control at the receiver and hold down the
key for about four seconds. The display will show the mes-
sage "ERROR POSITION" as in the figure.
VV
Contact a Jacuzzi
®
service centre .

THE HYDROMASSAGE STOPS BY ITSELF

VV
First of all, check that the main switch on the power supply
line of the tub is on and that there is not a power outage. Also
make sure you have complied with the instruction provided in
the relative chapter.
Each hydromassage cycle has its own duration. At the end
of that period, the hydromassage shuts down automatically.
Refer to the relative chapter to re-start it.
If there are any other irregularities, please refer to the following
instructions.
I
Defects concerning the electronics box
VV
Refer to the paragraph entitled "Hydromassage does not start".
I
Electronic safety cut-out protection in operation.
VV
Refer to the paragraph entitled "Hydromassage does not start".
I
Decrease of level of water in tub.
This may occur if the drain is accidentally opened, or also if the
user gets out of the tub.
The manner in which the anomaly is displayed is the same as in the
chapter "Hydromassage does not start - insufficient water level".
Proceed as follows to restore tub operation:
VV
You will need to add the required amount of water within five
minutes from the appearance of the alarm. The function will pick
up where it left off and continue until the end. If the water lev-
el is not restored within 5 minutes, the function is permanently
interrupted.
To return to normal remote control display, press any key.
ONLY A FEW AIR BUBBLES ARE COMING OUT OF THE
BIGGEST HYDROMASSAGE OUTLETS
VV
Check that the nozzles are open and turn them counter-clock-
wise as necessary.
HYDROMASSAGE EFFICIENCY IS DIMINISHED
VV
Check that the nozzles are open and turn them counter-clock-
wise as necessary.
VV
Clean the intakes as described in the chapter on mainte-
nance. If the problem persists, also clean the hydromassage out-
lets on the walls of the tub, again as described in the chapter on
maintenance
THE DISINFECTION CYCLE WILL NOT START
VV
First of all, check that the main switch on the power supply
line of the tub is on and that there is not a power outage. Also
make sure you have complied with the instructions provided in
the relative chapter. Make sure the remote control is pointed at
the receiver when confirming function start-up.
VV
Hold down the start button for at least four seconds, other-
wise the command will not be accepted.
If there are any other irregularities, please refer to the following
instructions.
I
Defects concerning the electronics box
VV
Refer to the chapter entitled "Hydromassage does not start".
I
Electronic safety cut-out protection in operation.
VV
Refer to the chapter entitled "Hydromassage does not start".
110