1 Overview
• Easy and secure access to system data with VBus.net
• Use of further solar and heating apps via VBus.net
• Comfortable system parameterisation via the RESOL RPT Parameterisation
Tool possible
• Software updates
• Economical solution for remote controller access
• Easy installation in only three steps
technical data
Housing: plastic
Protection type: IP 20 / EN 60529
Protection class: III
Ambient temperature: 0 ... 40 °C
Dimensions: 95 × 70 × 25 mm
Mounting: wall mounting (optional)
Display: operating control LED
Interfaces: RESOL VBus
for the connection to the controller, 10/100 Base TX
®
Ethernet, Auto MDIX, WLAN 2.4~2.4835 GHz
Power consumption < 1.75 W
Power supply:
input voltage of mains adapter: 100 ... 240 V~ (50 ... 60 Hz)
nominal current: 146 mA
input voltage of communication module: 12 V DC ± 5 %
20
2 Included
1
2
3
If one of the items mentioned below is missing or defective, please contact your
distributor:
1 KM2 Communication module with mains adapter, VBus
2 Interchangeable mains adapter plugs (EURO, UK, USA, AUS)
3 Network cable (CAT5e, RJ45), 2 m
4 Wall plugs, screws and rubber pads
5 Terminal block for extending the VBus
Manual (not shown)
5
4
cable pre-connected
®
cable
®