Programmable Multiband Amplifier
TMB 200 & TMB 200S
UHF filters setup.
AMP IN
XX1
p
UHF CHAN
UHF CHAN
Menu
F1 21-25
F1 21-25
p
CHAN UHF
UHF CHAN
Menu
Fx
31
Fx 31-31
p
•
Unit in standby mode, push a button to reach the SETTINGS/Config menu.
•
Press the button until the display shows the UHF CHAN / Fx menu.
•
Press Menu button to enter the function
•
Press the buttons + or - to change the start channel
•
Confirm by pressing Menu
•
Press the buttons + or - to change the end channel
•
Confirm by pressing Menu
•
Proceed the same way for the other channels
Note:
•
In LTE 21-60 only channel 21 to 60 are available.
•
A offset function offers a fine tuning
Setting the levels.
There are three types of level setting:
•
"Manual" setting of output levels (menu Fx / Att 20)
•
"Manual" setting of output levels FM VHF and UHF (menu UHF / Att, VHF / Att , FM / Att)
•
automatic UHF channel gain control (Auto lvl menu)
Note :
•
Display20 = 0 dB attenuation
awi -july 14
+
UHF CHAN
Menu
-
F1 21
- __
+
UHF CHAN
Menu
-
Fx 31
- __
14
+
Menu
-
+
3s
UHF CHAN
-
Tun -9 +9
+
Menu
-
+
3s
UHF CHAN
-
Tun -9 +9
Menu
Menu
TMB 200-V1