Mechanical faults on pumps
Fault
Air pockets in the lubricant or lubrication system
Reservoir vent is clogged
Suction bore of pump element is clogged.
Piston of pump element is worn
Defective check valve in the pump element
Defective pressure relief valve
Blockade on a lubrication point or in the SSV me-
tering device
44
Possible cause/ recognizability of fault
○ Visual check for bubbles in the lubricant
○ Visually check whether there is lubricant in the
reservoir vent.
○ After disassembling the pump element
○ Too low pressurization
○ Lubricant leaking from the pressure reducing
valve
If the fault cannot be determined and remedied, please contact our Customer Service.
10. Troubleshooting
Remedy
○ Vent lubricant (if required, trigger several ad-
ditional lubrication cycles)
○ Remove lubricant from the reservoir venting
device
○ Disassemble and clean the pump elements.
○ Replace pump element.
○ Replace pressure relief valve.
Check the lubrication point and the SSV mete-
ring device and remedy fault, if necessary.