Tips And Recommendations; Problems With The Lighting Mod/Var Ramp Rts-Lb1; Replacing A Lost Or Broken Control Point - SOMFY RTS-LB1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
Installation guide
7.3.2 From a standard control point
A standard control point is a three button control point (Up/Stop-my/
Down).
1)
Press the STOP/my button to switch on the ramp in the preset
favourite position.
2)
Press and hold the up or down buttons to adjust the light intensity
as required.
3)
Once the required level of light intensity has been reached, press
the STOP/my button until the ramp comes on then goes out:
-
The new favourite light intensity level has been programmed and
the ramp will come on at this level.

8. Tips and recommendations

8.1 Problems with the Lighting Mod/Var Ramp RTS-LB1?

Problems
Pressing a button on the RTS control
point has no effect on the Lighting
Mod/Var Ramp RTS-LB1.
The
Lighting
Mod/Var
RTS-LB1 does not provide suffi cient
lighting.
The
Lighting
Mod/Var
RTS-LB1 does not come on.

8.2 Replacing a lost or broken control point

Caution: This reset is carried out if all the RTS control points have been lost or broken.
Caution! This reset deletes all control points but retains the programmed favourite light intensity.
Caution! Only switch off the power to the Lighting Mod/Var Ramp RTS-LB1 to be reset!
Caution! Do not use an Inis RT/Inis RTS control point for resetting
1) Cut the power supply for 2 seconds.
2)
Switch the power supply back on for approximately 10 seconds (for
at least 5 seconds but no longer than 15 seconds).
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on: the ramp will fl ash slowly.
5)
Briefl y press the PROG button on the new RTS control point (f):
-
the ramp will come on then go out to indicate that the new RTS
control point has been programmed into the Lighting Mod/Var
Ramp RTS-LB1.
Copyright © 2008 - 2010 Somfy SAS. All rights reserved.
Possible causes
The power supply is faulty.
The RTS control point has not been
programmed into the Lighting Mod/
Var Ramp RTS-LB1.
The RTS control point used is not
compatible with the Lighting Mod/Var
Ramp RTS-LB1.
The batteries in the RTS control point
are weak.
Ramp
The lighting power of the Lighting
Mod/Var Ramp RTS-LB1 is not
suffi cient.
Ramp
The lighting lamp or lamps are blown
or broken.
Lighting Mod/Var Ramp RTS-LB1
1
+
100%
2
-
-
-
0%
3
Solutions
Check the power supply.
Follow the procedure for programming
an RTS control point.
Ensure
the
two
products
compatible.
Replace the batteries.
See the lighting power in the
technical data.
Replace the lighting lamp(s).
1
2
OFF
ON
2 sec.
OFF
3
4
ON
2 sec.
5
PROG.
A
F
are
10 sec.
...
39

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

5061612b

Tabla de contenido