AC/DC Voltage and Voltage Frequency Measurement (Picture 3)
1) lnsert the red test lead into the "V °C
2) Turn the function switch to the AC/DC voltage position, and connect the test leads with the
measured load or power supply in parallel.
Note
• Do not input voltage above 600V. Although it is possible to measure higher voltage, it may
damage the meter.
• Be cautious to avoid electric shock when measuring high voltage.
• When the measured voltage is ≥30V (AC) or ≥60V (DC), the LCD will display the high
voltage alarm prompt.
Resistance Measurement (Picture 4)
1) lnsert the red lest lead into the "V °C
2) Turn the function switch to the "Ω" posilion, press the SELECT button to select resistance
measurement, and connect the test leads with both ends of the measured resistance in
parallel.
Ω
Hz" jack, black into the "COM" jack.
Red
Black
Picture 3
Ω
Hz" jack, black into the "COM" jack.
Capacitance
Continuity
Diode
Resistance
Red
Black
Picture 4
21