figure 2
4
The inner tank includes a vapor outlet connected
to a automatic extraction (no.4 Figure 2) and two
anchors trigger (no5 figure 2) to maintain the spray
guns open during cleaning.
The lower zone is designed to introduce two
containers of solvent for recirculating and clean
solvent, the total amount introduced of these two
solvents should not exceed the total capacity of
the recirculation tank to prevent overflow.
The equipment "COMPACT 220 'is provided with
an enrollment that informs:
Brand commercializing company
Name and address
CE Mark
Model
Number Enrolment
Serial number
Weight
Altura
Long
Width
Sustainable load
Washing solvent volume zone
Maximum working pressure
5
4. EQUIPMENT IDENTIFICATION
5. TECHNICAL DATA
50 kg.
1000 mm.
480 mm.
550 mm.
20 kg.
38 L.
10 Bar.
- 14 -
This lower area has two absorptions, one with inlet
filter (no. 3 and 6 figure 3) to be introduced in the
solvent tank for recirculating it through a diaphragm
pump (no. 4 Figure 3) allows a second use. The
other absorption (no 7 Figure 3) will be introduced
into the clean solvent tank.
This absorption of clean solvent is for automatic
cleaning (through the diaphragm pump) either a
timed way or manually by a pushbutton. In each
case the clean solvent will return to the tank through
the drain (no 8 figure 3).
3
Construction year
8
figure 3
4
6
7