Descargar Imprimir esta página

Technical Features - Sime MURELLE 25 OF ErP Manual De Instrucciones

Ocultar thumbs Ver también para MURELLE 25 OF ErP:

Publicidad

Idiomas disponibles

Idiomas disponibles

1.3 
TECHNICAL FEATURES
Models MURELLE 
Heat output nominal (Pn max).
Heat output reduced (Pn min).
Heat input  (*) 
Nominal.(Qn.max.-.Qnw.max).
Reduced.(Qn.min.-.Qnw.min).
Thermal yield 100% useful 
Thermal yield useful at 30% of load 
Losses after shutdown to 50°C (EN 15502) 
Supply voltage 
Adsorbed power consumption (Qn max - Qn min) 
Electrical protection grade 
Energy efficiency
Seasonal.energy.efficiency.class.of.the.heating.system.
Seasonal.energy.efficiency.of.the.heating.system.
Sound.power.of.the.heating.system...........
D.H.W..energy.efficiency.class.
D.H.W..energy.efficiency..
D.H.W..load.profile.declared.
C.H. setting range.
Water content boiler.
Maximum water head (PMS) 
Maximum temperature (T max) 
Expansion vessel capacity 
Expansion vessel pressure 
D.H.W. setting range.
D.H.W. flow rate (EN 13203).
Continuous D.H.W. flow rate (∆t 30°C).
Minimum D.H.W. flow rate.
D.H.W pressure min/max (PMW).
D.H.W. pressure min. nom. power 
Smokes temperature min/max.
Smokes flow min/max.
CO
2
NOx measured 
PIN number 
Category 
Type of appliance 
NOx emission class.
Weight when empty.
Main burner nozzle 
Quantity.nozzles.
G20.nozzle.diameter.
G30/G31.nozzle.diameter.
Gas consumption (**)
Natural.gas.(G20).
LPG.(G30/G31).
Burner gas pressure min/max
(G20).
(G30.-.G31)..
Gas supply pressure
Natural.gas.(G20).
Butane.(G30).
Propane.(G31).
.(*)... Heat.input.of.the.heating.system.measured.using.lower.heating.value.(LHV)
.(**). Gas.consumption.figures.express.the.lowest.calorific.power.of.pure.gas.under.standard.conditions.at.15°C.–.1013.mbar;.this.figure.may.differ.from.the.
actual.figure,.which.is.dependent.on.gas.composition.and.environmental.conditions..
25 OF ErP 
kW.
23.0.
kW.
8.7 
kW.
25.5 
kW.
10.2 
90.0.
91.1.
W.
152.
V-Hz.
230-50.
W 
54.-.47.
IP.
X4D 
.
%.
dB.(A).
.
%.
.
°C.
20÷80.
l.
7.1.
bar.(kPa).
3.(294).
°C.
l.
bar.(kPa).
1.(98).
°C.
10÷65.
l/min.
10.7.
l/min.
10.9.
l/min.
2.4.
bar.(kPa).
0.2/7.(19.6/686).
bar.(kPa).
0.5.(49).
°C.
88/122.
g/s.
18/20.
%.
5,2.
mg/kWh.
140.
1312BU5345.
II2H3+.
B11BS.
.
3.(‹150.mg/kWh).
kg 
n°.
mm.
1.30.
.mm.
0.77.
m
3
/h.
2.70.
kg/h.
2.01.
mbar.(kPa).
1.8/11.0.(0.18/1.08).
mbar.(kPa). 4.7/27.7.(0.46/2.71).-.4.7/35.7.(0.46/3.50).
mbar.(kPa).
20.(1.96).
mbar.(kPa).
28–30.(2.74-2.94).
mbar.(kPa).
37.(3.63).
C.
78.
49.
B.
78.
XL.
85.
7.
30.
12.
4.8/27.7.(0.47/2.71).-.4.8/35.7.(0.47/3.50)
30 OF ErP
27.0
10.2
30.0
12.0
90.0
91.5
179.
.
230-50
54.-.47
X4D
C.
.
79
49
B
78
XL
20÷80
8.0
3.(294)
85
8
1.(98)
10÷65
12.7.
12.9
2.4
0.2/7.(19.6/686)
0.65.(63.7)
95/135
18/20
6,2
138
1312BU5345
II2H3+
B11BS
3.(‹150.mg/kWh)
33
14
1.30
0.77
3.17
2.37
1.9/11.1.(0.19/1.09)
20.(1.96)
28–30.(2.74-2.94)
37.(3.63)
65
ES
PT
ENG

Publicidad

loading

Este manual también es adecuado para:

Murelle 30 of erp