and. deposits,. the. use. of. inhibitors. such. as.
Sentinel X100 or Fernox Protector F1. is.
10. .Visualizzazione.ore.di.funzionamento.del.bruciatore.in.h.x.100.(es..14.000.e.10)
recommended.after.cleaning.the.system..
It. is. important. to. check. the. concentration.
of.the.inhibitor.after.each.system.modifica-
tion. and. during. maintenance. following. the.
manufacturer's. instructions. (specific. tests.
are.available.at.your.dealer)..
The.safety.valve.drain.must.be.connected.to.
a.collection.funnel.to.collect.any.discharge.
during.interventions..
11. .Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
If. the. heating. system. is. on. a. higher. floor.
than. the. boiler,. install. the. on/off. taps. sup-
plied. in. kit. optional. on. the. heating. system.
delivery/return.pipes..
WARNING: Failure to clean the heat system
or add an adequate inhibitor invalidates
the device's warranty.
12. .Visualizzazione.codice.errore
.......ultima.anomalia
Gas.connections.must.be.made.in.accordan-
ce. with. current. standards. and. regulations..
When. dimensioning. gas. pipes. from. the.
meter.to.the.module,.both.capacity.volume.
(consumption).in.m
3
/h.and.gas.density.must.
be.taken.into.account..
The. sections. of. the. piping. making. up. the.
13...Visualizzazione.codice.errore
system.must.be.such.as.to.guarantee.a.sup-
.......penultima.anomalia
ply. of. gas. sufficient. to. cover. the. maximum.
demand,.limiting.pressure.loss.between.the.
gas.meter.and.any.apparatus.being.used.to.
not.greater.than:
–. 1.0.mbar.for.family.II.gases.(natural.gas);
–. 2.0. mbar. for. family. III. gases. (butane. or.
propane).
14...Visualizzazione.numero.totale
.......delle.anomalie
An.adhesive.data.plate.is.sticked.inside.the.
front.panel;.it.contains.all.the.technical.data.
identifying.the.boiler.and.the.type.of.gas.for.
which.the.boiler.is.arranged.
2.3.1
Filter on the gas pipe
15. .Contatore.accessi.parametri
The.gas.valve.is.supplied.ex.factory.with.an.
.......installatore.(es..140.accessi)
inlet.filter,.which,.however,.is.not.adequate.
to.entrap.all.the.impurities.in.the.gas.or.in.
gas.main.pipes..
To.prevent.malfunctioning.of.the.valve,.or.in.
certain.cases.even.to.cut.out.the.safety.devi-
ce.with.which.the.valve.is.equipped,.install.
16. Contatore.accessi.parametri
.......OEM.(es..48.accessi)
an.adequate.filter.on.the.gas.pipe.
2.5
SYSTEM FILLING (fig. 4)
Filling.of.the.boiler.and.the.system.is.done.
by.the.system.filling.(11)..
The.charge.pressure,.with.the.system.cold,.
must.be.between.1 and 1.5 bar..
During.system.filling.you.are.recommended.
to.keep.the.main.switch.turned.OFF..
Filling. must. be. done. slowly. so. as. to. allow.
any. air. bubbles. to. be. bled. off. through. the.
air.valves..
Should. the. pressure. have. risen. well. above.
the.limit.expected,.discharge.the.over.pres-
sure.by.opening.the.pressure-relief.valve.
2.5.1
Emptying the system (fig. 4)
Use. the. drain. tap. to. empty. the. system. (7)..
Turn.off.the.boiler.before.doing.this.
2.6
FLUES/CHIMNEYS
A.chimney.or.flue.for.the.evacuation.of.the.
combustion. products. into. the. atmosphere.
must. correspond. to. the. requisites. prescri-
bed.by.the.laws.in.force..
2.11
ELECTRICAL WIRING
If.you.must.replace.the.electric.power.cable.
supplied.with.the.boiler,.order.it.exclusively.
from.Sime..
The. power. supply. must. be. single-phase.
230V. -. 50. Hz. through. a. main. switch. pro-
tected.by.a.fuse.with.a.distance.of.at.least.3.
mm.between.contacts.
The boiler must be connected with an effi-
cient grounding system. SIME shall not be
held liable for injury or damage resulting
from failure to ground the boiler.
ATTENTION: Before every intervention on
the boiler, cut off the electricity supply by
means of the main switch of the system,
since even if the boiler is "OFF", the elec-
trical panel remains connected to the elec-
tricity.
2.11.1 Chronothermostat connection
Connect. the. chronothermostat. as. indica-
ted. in. the. boiler. electrical. diagram. (see
paragraph 2.12). after. having. removed. the.
existing.bridge..
The. chronothermostat. to. be. used. must. be.
of. a. class. conforming. to. the. standard. EN.
607301.(clean.electrical.contact).
2.11.2 Remote control SIME HOME
connection (optional)
The. boiler. is. designed. for. connection. to. a.
remote. control. unit. SIME.HOME,. supplied.
on.request.(code.8092280/81).
The.remote.control.unit.SIME.HOME.allows.
for.complete.remote.control.of.the.boiler..
The. boiler. display. will. show. the. following.
message:
For.installation.and.use.of.the.remote.con-
trol,.follow.the.instructions.in.the.package.
NOTE: Ensure PAR 10 set to 1 (PAR 10 = 1).
2.11.3 External sensor connection
The.boiler.is.designed.for.connection.to.an.
external. temperature. sensor,. supplied. on.
request. (code. 8094101),. which. can. auto-
matically.regulate.the.temperature.value.of.
the. boiler. output. according. to. the. external.
temperature.. For. installation,. follow. the.
instruction.in.the.package..