Connection With The Mains; Operation; Cleaning And Maintenance - EuroLite Super Pinspot PAR-56 Manual Del Usuario

Ocultar thumbs Ver también para Super Pinspot PAR-56:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connection with the mains

The electric connection must only be carried out by a qualified electrician!
In order to connect the device to the mains, you have to install a power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
Connect the device to the mains with the power-plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.

OPERATION

After you connected the effect to the mains, the Super Pinspot starts running.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
All manuals and user guides at all-guides.com
DANGER TO LIFE!
DANGER TO LIFE!
14/27
5080310A_V_1_0_4946.DOC