12c
Fire-rated wood door only: Peel adhesive backing
from intumescent. Apply intumescent to armor front
plate.
CAUTION
Intumescent must be properly aligned before adhesive contacts
the armor plate. Adhesive is permanent and not repositionable.
12d
Install armor front plate.
13

Install interior lever assembly

13a
Tighten screws on the interior mounting plate
assembly.
13b
Install the interior lever assembly.
By hand only, thread the bushing on the mounting plate.
Rose trim
Escutcheon trim
Bushing
L For interior escutcheon trim with thumbturn see step 13c.