Going Away on Vacation
When not using the dispenser for long periods of time or when going on vacation, conserve energy, unplug the dispenser
and drain the reservoirs (see Draining the Reservoirs). Follow Initial Product Cleaning Procedures upon return and
startup of the dispenser.
SPECIFICATIONS
GWD5440W / GWD5440BLS
Heating Temp (approx.):
Cooling Temp (approx.):
Output per hr:
Internal Tank:
Power Consumption:
TROUBLESHOOTING TIPS
Problem
Water dispenser or
dispensing button is
leaking
Water is not hot or cold
enough
6
Hot
1.2 gal / 4.6 L
0.2 gal / 0.6 L
1150 W
Possible Cause
Small pin hole or crack in the bottle,
(common with recycled water bottles).
Drain cap and silicone seal are not secure.
Water was poured directly into bottle
support collar and overflowed.
Possible air pocket.
All the water in the tank has been used.
The unit is unplugged.
"Kettle" Feature was not activated.
The circuit breaker in your home is
tripped or the fuse has blown.
Temperature limit tripped.
Thermostat needs to be adjusted colder.
194°F / 90°C
35 - 52°F / 2°C - 11°C
Cold
0.5 gal / 2.0 L
0.8 gal / 3.6 L
88 W
Suggested Solution
Conduct water bottle leak test outlined on
page 3.
Ensure seal is secure in drain plug and
tighten drain cap.
Drain by pressing dispenser taps.
Press several times to relieve air pocket and
release to re-set valve.
Replace with full bottle and wait; 60 minutes for
water to cool, 3 minutes for water to heat (after
activating "Kettle" feature button).
Plug it into the outlet.
Activate "Kettle" Feature by pressing the button.
Reset the breaker or replace the fuse.
Allow the temperature of the hot water tank to cool
for approximately 15-30 minutes. The temperature
limit thermostat will re-set automatically once
sufficiently cooled, and the cooling system will
reactivate automatically. To operate the hot water
system, press the Insta-Hot button.
Adjust thermostat between high (cool) and low
(colder) levels to achieve desired temperature.
7