Im portant Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual
contains important instructions that should be
followed during installation, operation, and
maintenance of the product. Save this manual
for future reference.
This is the safety alert symbol. When you
see this symbol on your pump or in this manual,
look for one of the following signal words and
be alert to the potential for personal injury!
indicates a hazard which, if not
avoided, will result in death or serious injury.
indicates a hazard which, if not
avoided, could result in death or serious injury.
indicates a hazard which,
if not avoided, could result in minor or
moderate injury.
NOTICE addresses practices not related to
personal injury.
Description
This submersible sump pump is designed for
home sumps. The permanent split capacitor
motor is oil filled, sealed for cooler running,
and has automatic-reset thermal protection.
Ball bearings on the motor shaft never need
lubrication. The power cord is a 3-wire,
grounding-type cord.
Specifications
Power supply required .................................. 115V, 60 HZ.
Liquid Temp. Range ......................... 32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ............15 Amps
Motor Full Load: (1/2 HP) ....................................6.9 Amps
Discharge ....................................................... 1-1/2" FNPT
NOTICE Do not reduce size of discharge pipe or
hose below 1-1/4" diameter. If discharge is too
small, pump will overheat and fail prematurely.
This pump is designed for use in a residential
sump only. Pump water only with this pump.
Performance
5' (1.5m)
4320 (16 353)
3660 (13 855)
All manuals and user guides at all-guides.com
GPH (LPH) at Total feet (m) of lift
10' (3m)
15' (4.6m)
Capacity Gallons(L)/Hour
2640 (9 993)
NOTICE This unit is not designed as a waterfall
or fountain pump, or for applications involving
salt water or brine! Use with waterfalls,
fountains, salt water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming
pool drainer.
General Safety Information
Electrically powered sump pumps normally
give many years of trouble-free service when
correctly installed, maintained, and used.
However, unusual circumstances (interruption
of power to the pump, dirt/debris in the sump,
flooding that exceeds the pump's capacity,
electrical or mechanical failure in the pump,
etc.) may prevent your pump from functioning
normally. To prevent possible water damage
due to flooding, consult your retailer about
a secondary AC sump pump, a DC backup
sump pump, and/or a high water alarm. See
Troubleshooting in this manual for information
about common sump pump problems and
remedies. For more information, see your retailer
or call customer service.
1. Know the pump application, limitations, and
potential hazards.
2. Do not use in water with fish present. If any oil
leaks out of the motor it can kill fish.
3. Disconnect power before servicing.
4. Release all pressure within system before
servicing any component.
5. Drain all water from system before servicing.
6. Secure discharge line before starting pump.
An unsecured discharge line will whip,
possibly causing personal injury and/or
property damage.
7. Check hoses for weak or worn condition
before each use, making certain that all
connections are secure.
8. Periodically inspect sump, pump and system
components. Keep free of debris and foreign
objects. Perform routine maintenance
as required.
9. Do not run pump whose discharge line can be
shut-off or obstructed.
20' (6m)
1020 (3 861)
2
No flow at height
shown below
22' (6.7m)