Maintenance

Cleaning Strainer
WARNING: To reduce the risk of
injury
from
unplug power cord before cleaning
strainer.
Your pump requires no additional lubrica-
tion or maintenance beyond keeping it
clean and free of debris.
Cleaning
Before storing the pump, it should be
cleaned.
To clean the Pump Accessory, rinse out
your vac drum so that it is free of any
debris. Fill the drum 3/4 of the way full with
clean water and allow the pump to pump
the water out. For vacuums under 12-gal-
lons, perform this procedure twice.
Remove the remaining water from the
drum; remove the Pump Accessory from
the drain and install the supplied drain cap
to the permanently installed drain adapter.
To keep your pump looking its best, clean
the outside with a cloth dampened with
warm water and mild soap. Remove any
excess water or debris with a dry cloth.

Troubleshooting

Problem
No Flow/Restricted Flow
Unit Does Not Turn On
Leaking
Odor (Electrical)
12:49 PM
Page 10
accidental
starting,
1. Check strainer for clog.
2. Make sure water is in vac drum.
3. Check shut-off valve.
4. Check for kink in hose.
5. Make sure hose outlet does not
exceed 50 feet.
1. Check GFCI - see page 8.
2. Make sure Pump Accessory is plugged in.
3. Make sure switch is on.
4. Check house circuit breaker/fuse.
1. Check fit on adapter.
2. Check coupler fit and "O" ring.
3. Check shut-off valve fit and "O" ring.
4. Check garden hose fit and make sure hose
washer is in place.
1. Unplug Pump Accessory.
2. Check for blockage.
3. If Pump Accessory continues to have an electrical
odor, return to an Independent Service Center.

Cord Storage

Wrap the cord up and use the attached
hook & loop strap to retain the cord.
Storing the Pump Accessory
When not in use, store your Pump
Accessory in a cool, dry location with the
cord wrapped up using the supplied hook
& loop cord wrap.
WARNING: Extreme temperatures
can cause the motor seal to fail,
allowing water into the motor.
The original Wet/Dry Vac drain cap should
then be installed on the drain adapter that
has been permanently attached to the drain
of your Wet/Dry Vac.
WARNING:
To
SAFETY and RELIABILITY, repairs
and adjustment should be performed
by Independent Service Centers,
always using RIDGID replacement
parts.
Remedy