2- Technical Data - Vimar Elvox EIM1 Manual Para El Conexionado Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
HIDDY
N.B.: It is necessary to have a wall-mounted junction box between the control panel and the actuator so as to avoid making junctions or shunting inside the
foundation box. The actuator cable is 2 metres long. Therefore the ducting from the foundation box to the junction box must not exceed a length of 1.7 metres.
Technical data:
Electric motor supply voltage
Electric motor maximum absorption
Electric motor maximum power
Maximum gate leaf length
Maximum gate leaf weight
Maximum opening
Protection rating
Operating temperature
Frequency of use
Dimensions and clearance of underground actuator EIM1:
Dimensions and clearance of foundation box ZX41:
12
Description
Opening time
Dimensions
Weight
EIM1
24 Vdc
6 A
144 W
2 metres
200 kg
180°
Min. 12sec. Max 22 sec.
IP67
From -20 to +55°C
365x147x97 mm
8 kg
100%
134
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido