Seav L B 2150 Serie Manual Del Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
ELECTRONIC PANEL LXB 2150
Single-phase electronic control unit for the automation of 1 – 2
swing gates with Bluetooth 4.2 module and incorporated radio
receiver, in a 9-pin DIN bar container.
- Mod. LGB 2150
- Mod. LSB 2150
- Mod. LHB 2150
I
MPORTANT FOR THE USER
- The device can be used by children over 8 years of age
and persons with reduced physical or psychological
abilities or with little knowledge and experience only if
supervised or educated in its operation and safe use, in
order to also understand the dangers involved in its use.
- these instructions are also available on the
http://www.seav.it
website
- Do not allow children to play with the device and keep
the remote controls out of their reach.
- Frequently examine the system to detect any signs of
damage. Do not use the device if it is in need of repair
work.
-Always remember to disconnect the power supply before
carrying out any cleaning or maintenance.
- Cleaning and maintenance must not be carried out by
unsupervised children
- ATTENTION: keep this instruction manual safe and
observe the important safety requirements contained
herein. Failure to comply with the requirements may
cause damage and serious accidents.
I
MPORTANT FOR THE INSTALLER
15) Before automating the frame, check that it is in good
condition, in compliance with the Machinery Directive
and with EN 12604.
16) Check that the location where the installation is
located enables compliance with operating temperature
limits specified for the device.
17) The safety of the final installation and compliance
with all prescribed Standards (EN 12453 - EN 12445) is
the responsibility of the person who assembles the
various parts to construct a total closing.
18) Use safety devices capable of monitoring the status
of their connection to the electrical control unit.
19) Once installation is finished, it is recommended that
all
necessary
checks
programming of the control panel and correct installation
of safety devices) to ensure that compliant installation
has been performed.
20) The control unit does not have any type of isolating
device for the 230 Vac line. It is therefore the
responsibility of the installer to set up an isolating device
inside the system. It is necessary to install an omnipolar
switch, surge category III. It must be positioned to
provide protection from accidental closing, pursuant to
point 5.2.9 of EN 12453.
: Without radio receiver
: 433.92 Mhz "narrow band"
: 868.3 Mhz "narrow band"
be
performed
(appropriate
GB
21) Cables for power and connection to the motor must
have an outside diameter between 4.5 and 7 mm. The
internal conductor wires must have a nominal section of
0.75mm2. If a raceway is not used, use H05RR-F
cables. Pay careful attention when fastening the cables
so that they are anchored in a stable manner.
22) The gear motor used to move the frame must
comply with the requirements of point 5.2.7 of EN 12453.
23) In compliance with 5.4.2 of EN 12453, it is
recommended to use gear motors equipped with an
electrical-mechanical release device, so that the frame
can be moved manually in case of necessity.
24) In compliance with 5.4.3. of EN 12453, use
electrical-mechanical release systems or similar devices
which stop the frame safely in the end run position.
25) The various electrical components external to the
control unit must be cabled in accordance with standard
EN 60204-1 as amended, and as set forth in point 5.2.7
of EN 12453
26) The assembly of a push button panel for manual
control must be completed positioning the push button
panel in such a way that the user is not placed in a
dangerous position.
27) The safety function ensured by the control unit is
active only during closing, therefore, protection on
opening must be ensured in the installation phase with
measures (guards or safety distances) independent of
the control circuit.
28) For proper functioning of the radio receiver, if using
one or more control units, the installation at a minimum
distance of at least 3 metres one from the other is
recommended.
The electronic control unit:
LGB 2150 - LSB 2150 – LHB 2150
they comply with the specifications of the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.
The full text regarding the EU Declaration of Conformity is
available from the following Internet address:
http://www.seav.it/
5
rev. 1.2
09/07/2019

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lgb 2150Lsb 2150Lhb 2150

Tabla de contenido