T. MOT : (Manual Programming of the motor operating time.)
The control unit can be used to manually program the Motor
Time in every single operating phase.
The programming procedure must be carried out with the gate
closed as follows: press the T. MOT key of the SEAV "BeTech"
application for an instant via Smartphone, the Motor will begin
the opening cycle. When the desired initial point of deceleration
is reached, press the T. MOT key of the application again, at
the same time the motor will decelerate until it reaches the
desired position; press the T. MOT key of the application to
finish the opening cycle. Subsequently, the T. MOT. key will
start flashing quickly. Now repeat the motor time and the
deceleration programming operation for the closing cycle. If you
do not want the control unit to decelerate, when the opening
and closing phase is finished, press the T. MOT key of the
application twice during programming, instead of just once.
T. MOT. PED:
(Programming pedestrian operating time)
The control unit can be used to manually program the
Pedestrian Motor Time in every single operating phase.
The programming procedure must be carried out with gate
closed as follows: press the T. MOT PED key of the SEAV
"BeTech" application for an instant via Smartphone, the Motor
will begin the opening cycle. When the desired initial point of
deceleration is reached, press the T. MOT PED key of the
application again, at the same time the motor will decelerate
until it reaches the desired position; press the T. MOT PED key
of the application to finish the opening cycle. Subsequently, the
T. MOT. PED key will start flashing quickly. Now repeat the
motor time and the deceleration programming operation for the
closing cycle. If you do not want the control unit to decelerate,
when the opening and closing phase is finished, press the T.
MOT PED key of the application twice during programming,
instead of just once.
DOOR DEL. T.
: (Programming door delay of 15 sec. Max.)
The control unit is supplied by the manufacturer without gate
delay during opening and closing. The time can be selected
thanks to the dedicated application SEAV "BeTech".
Follow Me :
The electronic control unit, using the dedicated application
SEAV "BeTech" via Smartphone, allows to set the Follow Me
function: this function can only be programmed if a Pause
Time has already been programmed and it is used to shorten
the Pause time to 5 sec after the photocell disengages, i.e.
the gate closes 5 seconds after the user has passed
through.
Soft Start :
The electronic control unit, using the dedicated application
SEAV "BeTech" via Smartphone, can be used to activate the
Soft Start function: this function will control the motor start-up,
gradually increasing the Motor power in the first 2 seconds of
operation.
Hydraulic Motors Pressure Maintenance :
The electronic control unit, using the dedicated application
SEAV "BeTech" via Smartphone, can be used to select the
Hydraulic Motors Pressure Maintenance function. Accordingly
the control unit will send a closing command every 2 hours to
the motor for 2 seconds.
Ramming effect :
The electronic control unit, using the dedicated application
SEAV "BeTech" via Smartphone, can be used to select the
Water Hammer function. Accordingly, we can facilitate the
release of the gate and therefore allow for the proper execution
of the opening phase. In fact, the control unit, before starting
the opening phase sends a closing command for 2 seconds
with power relative to the choice selected.
Closing boost :
The electronic control unit, using the dedicated application
SEAV "BeTech" via Smartphone, can be used to select the
Closing Boost function. Accordingly the control unit, if
functioning with Deceleration during closing, will reach (after
having completed the deceleration closing phase) a time of 1
second with power relative to the choice selected in order to
overcome the gate installed.
Electric Lock activation by CMD PED. :
The electronic control unit, using the dedicated application
SEAV "BeTech" via Smartphone, can be used to select the
Electric Lock Activation through the Pedestrian command
function.
This function is used when you have, for example, a gate with a
door next to it for Pedestrian passage.
Accordingly, the gate can be opened with the PUL commands
as well as from the Pedestrian door using the electric lock with
the PED commands.
Input Configuration :
The control unit is supplied by the manufacturer with the
possibility to Activate / Disablethe CN3 connector inputs or
modify the function, using the dedicated application SEAV
"BeTech".
Reset :
The control unit can be used to reset the control unit to default
settings through the dedicated application SEAV "BeTech";
press RESET and the control unit will emit a confirmation Beep.
Diagnostics :
Using the dedicated application SEAV "BeTech", the control
unit allows for the Real time monitoring of the status of all
INPUTS and OUTPUTS, the number of radio controls present in
the Memory and their Type and other information useful to the
installer.