Other Features - KENMORE ELITE 405.54571 Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

_/_Up/Down
Buffons
* Humidify Set Control BuffonsThe humidity levelcan be set within a range
of 35°/0 RH (Relative Humidity) to 85°/0 RH (Relative Humidity) in 5°/0
increments.For drier air, press the < Button and set to a lower percent value
{°/0).For damper air, press the > Button and set a higher percent value (°/0).
"TIMER Set Control Buffons
Use the Up/Down Buttons to set the Auto start and Auto stop time from
0 to 24 hours.
O
Timer Button
Pressto initiate the Auto start and Auto stop feature, in conjunction with
the < and > key Buttons.
Display
Shows the set % humidity level from 35% to 85% or auto start/stop time
{0~24) while setting, then shows the actual (+5°/0 accuracy) room °/0
humidity level in a range of 30°/0 RH (Relative Humidity) to 90°/0RH (Relative
Humidity).
Error Codes and Protection Cede:
AS- Humidity sensor error--Unplug
the unit and plug it back in. If error repeats,
arrange
for service.
ES- Temperature sensor error-- Unplug the unit and plug it back in. If error
repeats, arrange
for service.
P2- Bucket is full or bucket is not in right position--
Empty the bucket and
replace it in the right position.
EC- Unit Malfunction--Check
to verify that the surrounding temperature
is within
the range of 41°F: (5 °C) to 95 °F (35 °C). If the temperature
is not within range,
take action to correct
the surrounding
temperature.
If the EC code persists,
there is a malfunction
that requires you to call for service. Some causes of this
EC error code could be a refrigerant
leak, an overload
or failure of the
compressor, or blockage
in the sealed system.
E3- Unit malfunction--
Unplug the unit and plug it back in. If error repeats,
arrange
for service.
Eb- Bucket is removed or not in right position-- Replace the bucket in the right
position.
OTHER FEATURES
Bucket Full Light - Lights up when the bucket is ready to be emptied.
Auto Shut Off - The dehumidifier
shuts off after 30 seconds when the bucket is
full, or when the bucket is removed or not replaced in the proper position. When
the set humidity level is reached, the compressor will shut off, and the fan will
continue to run for another 3 minutes, and then shut off.
Auto Defrost - When frost builds up on the evaporator
coils, the compressor
will cycle off and the fan will continue to run until the frost disappears.
3 Minute Compressor Delay- Any time the compressor stops running for any
reason, such as when the humidity set point has been reached, it will not restart
again for a minimum of 3 minutes. This is a safety design to prolong the life of
the compressor.
If the fan has also stopped,
it will not restart again for 3
minutes or until the compressor
starts.
9

Publicidad

Tabla de contenido
loading

Tabla de contenido