This paragraph concerns a quick procedure to set the control unit and set it at work immediately.
We recommend following these instructions, in order to check quickly the correct operation of control unit, motor and accessories, and
then changing the configuration in case of any non-satisfactory parameter.
WARNING: The self-learning procedure must be performed when the encoder is to be used.
Please refer to the paragraph "Control unit configuration" for the item position inside the menu, as well as for the available options for
each item.
1. Call up a default configuration (item dEF.). Select AntE for a door-gate, select Scor for other configurations (sliding, rolling,
sectional, etc.).
2. If you have a door gate with only one motor, set t.AP2 opening time to zero.
3. In case there is no electric lock on the gate, set t.SEr, t.ASE and t.CvE values to zero.
4. Set items StoP, Fot1, Fot2, CoS1, CoS2 e FC.En according to the safety devices installed on the gate.
5. Start the self-learning cycle (item APPr).
This last operation will close the configuration menu and store set up parameters.
Self-learning procedure if there are two motors:
• In case the ends of stroke, the encoder or the obstacle sensor have been enabled, the doors will be activated in closing direction
until the stop end or the closing end of stroke is reached. Be sure that the leaves do not overlap.
• In case NEITHER the ends of stroke NOR the obstacle sensor have been enabled, be sure that the doors are completely closed when
the procedure starts.
• The doors will be activated in opening direction until the stop end or the opening end of stroke is reached.
• In case the sensors have not been enabled, or if you realize that they do not signal the position to the control unit, you must send a
first START command when leaf 1 reaches its max. opening position and then a second START command when leaf 2 completes its
opening phase.
• The doors will be activated in closing direction until the stop end or the closing end of stroke is reached
• In case the sensors have not been enabled, or if you realize that they do not signal the position to the control unit, you must send a
first START command when leaf 1 reaches its fully closed position and then a second START command when leaf 2 completes its
closing phase.
Self-learning procedure if there is one motor:
• In case the end of stroke, the encoder or the obstacle sensor has been enabled, the door will be activated in closing direction until
the stop end or the closing end of stroke is reached.
• In case NEITHER the ends of stroke OR the obstacle sensor have been enabled, be sure that the door is completely closed when the
procedure is started up.
• The door will be activated in opening direction until the stop end or the opening end of stroke is reached.
• In case the sensors have not been enabled, or if you realize that they do not signal the position to the control unit, you must send a
START command when the door reaches its max. opening position.
• The door will be activated in closing direction until the stop end or the closing end of stroke is reached.
• In case the sensors have not been enabled, or if you realize that they do not signal the position to the control unit, you must send a
START command must be sent when the door reaches its fully closed position.
This paragraph concerns the step-by-step procedure to set all operation parameters of CITY1-ECD control unit. You can either
follow all procedure steps and perform a complete control unit configuration or select and adjust interesting items only.
As for both cases, you will have to perform the right exit procedure through item FinE, in order to activate your new configuration.
CITY1-ECD provides for a self-learning procedure of working times; therefore, we recommend that you set up a standard configuration
first (see previous paragraph), then you carry out the self-learning and finally you change any unsatisfactory items.
QUICK CONFIGURATION
CONTROL UNIT CONFIGURATION
Default value loading
The value of all menu items can be brought to a standard value (see
final recap table) by means of only one command. There are two sets of
values available:
AntE
SCor
After loading default values, the other menu items can be scrolled and
each parameter can be changed; exit from default menu will cause the
automatic selection of the next item.
34
Values for a two-leaf gate equipped with a lock.
Values for a one-leaf sliding gate without lock.