1. SPECIFICATION
Model Number
Open Flow Rate @ 13.6 V d.c.
Flow Rate @ 1m Head
Voltage D.C.
Weight
Recommended Fuse Size
Current Draw
Inlet Ports
Outlet Ports
Materials
* Flow rates are stated in accordance with ABYC recommendations at a voltage of 13.6 V d.c.
The Whale® Shower Waste System is designed to collect waste water from shower trays and sinks, then automatically
trigger the electric field sensor to activate the pump.
3. TO THE USER
Read the following instructions carefully before installation and use of equipment.
4. TO THE FITTER
Check that the product is suitable for the intended application, follow these installation instructions and ensure all
relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the end
user.
5. APPLICATION
This Whale Shower Sump System is designed for use in marine vessels to pump grey waste water only.
6. WARNINGS
1.
NOTE - This pump must not be mounted below the water line when connected to an intake or
outlet unless the system has a vented loop.
2.
POLARITY SENSITIVE - Reversed wiring will cause switch and pump failure.
3.
Do not cut wires as this will damage the connections and invalidate the warranty.
4.
Do not drill through hull, ensure that pump is mounted to additional board or bulkhead.
5.
NOT suitable for pumping flammable liquids, diesel, chemicals etc. For use in a grey waste water system only.
6.
The Whale® Shower Sump System is designed for installation in marine vessels only. If it is intended for use for
any other purpose or with any other liquid, it is the user's responsibility to ensure that the unit is suitable for the
intended use and, in particular, that the materials are fully compatible with the liquids to be used. The Whale®
Shower Sump System is NOT suitable for domestic applications.
7.
With all applications, it is important that a system of safe working practice is applied to installation, use and
maintenance. Ensure the electric supply is turned off before commencing installation.
7. PARTS LIST
1 x Whale® Shower Sump System including pump, switch and filter
8. INSTALLATION
WARNING: Please note that incorrect installation may invalidate the warranty.
Preparation - Always disconnect power sources before installing.
Location
1.
Sump must be lower than shower and all other drains
2.
Mount in a position with the shortest possible pipe run lengths.
3.
To ensure the electric field sensor switch correctly operates, the sump box must be mounted on a flat even
surface.
Whale
®
GW0500(B)
500 US GPH (32 ltrs/min)
315 US GPH (20 ltrs/min)
12V d.c.
1.25 kg (2.76 lbs)
2 Amps Automotive
1.5 Amps
¾" (19mm) / 1" (25mm) / 1 ⅛" (28mm) / 1 ½" (38mm)
Sump Box - ABS, Polycarbonate, Strainer - Stainless Steel, Pump body: ABS,
Pump Seals: Nitrile®, Pump Impeller - Acetal, Electric Field Sensor - ABS
2
Shower Waste System
GW0950(B)
950 US GPH (57 ltrs/min)
600 US GPH (38 ltrs/min)
12 V d.c.
1.42 kg (3.13 lbs)
5 Amps Automotive
4 Amps
¾" (19mm) / 1" (25mm)