4.3 Light signals and faults
The control panel has three LEDs that indicate the boiler operating status:
BOILER STATUS
Off status(OFF)
Stand-by
ACF alarm lockout module
ACF electronics fault alarm
Limit thermostat alarm
Tacho fan alarm
Water pressure switch alarm
NTC domestic water fault
NTC heating outlet fault
Heating outlet probe overtemperature
Outlet/return line probe differential alarm
NTC heating return line fault
Heating return line probe overtemperature
Outlet/return line probe differential alarm
Cleaning the primary heat exchanger
NTC flue gases fault
Flue gases probe overtemperature
False flame
Low temperature system thermostat alarm
Temporary pending ignition
Water pressure switch intervention
Calibration service
Calibration installer
Chimney sweep
Vent cycle
Preheating active function
Preheating heat request
External probe presence
Domestic water heat request
Heating heat request
Antifreeze heat request
Flame present
VISUALIZADOR
RED LED
OFF
-
on
A01
flashing
A02
0.5 on / 0.5 off
on
A03
on
A04
flashing
A06
0.5 on / 0.5 off
on
A07
on
A08
flashing
0.5 on / 0.5 off
A09
on
flashing
A11
0.2 on / 0.2 off
on
A77
flashing
ADJ
0.5 on / 0.5 off
ACO
flashing
0.5 on / 1.0 off
flashing
60°C
80°C
YELLOW LED
GREEN LED
flashing
0.5 on / 3.5 off
flashing
0.5 on / 3.5 off
on
flashing
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
flashing
flashing
0.5 on / 0.5 off
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
flashing
flashing
0.5 on / 1.0 off
0.5 on / 1.0 off
on
on
ENGLISH
TYPES OF ALARMS
None
Signal
Definitive lockout
Definitive lockout
Definitive lockout
Definitive lockout
Signal
Temporary stop
Temporary then
definitive
Definitive lockout
Temporary stop
Temporary then
definitive
Definitive lockout
Signal
Temporary stop
Definitive lockout
Temporary stop
Temporary stop
Temporary stop
Temporary stop
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
23