16-657-01
3. OPERATION AND PROGRAMMING
If the switcher is connected to the mains, the green LED on the CAMERA MODULE lights.
Settings DIP switch A
switch 1,2,3: for setting address
switch 4: for setting terminal resistor
ON DIP
1 2 3 4
address 0
ON DIP
1 2 3 4
address 1
ON DIP
If the camera interface is switched on, the external camera is activated and the red LED on the
1 2 3 4
module lights. The image of the external camera is displayed on all programmed internal units. You
ON DIP
can also control the camera manually by pressing the programming key (see fig.2). The camera is
then activated and the image is displayed on all programmed internal units.
1 2 3 4
Programming
Via the interface (16-651), you enter the system's programming or reset mode. For an exhaustive
description of the programming, see user manual of the 16-651.
The red LED on the camera interface gives feedback during programming:
- the red LED blinks at normal speed (1Hz): the system is still in programming or reset mode!
- the red LED blinks faster:
* in programming mode: the camera interface has sent its address (because you pressed the
programming key).
* in reset mode: the camera interface has deleted its address in all internal units (because you
pressed the programming key).
28
external unit 1
external unit 2
B
A
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
address 2
ON DIP
1 2 3 4
address 3
external unit 3
external unit 4
EN