RS17.P
Terminal block functions:
Terminal Description
L
Live
Earth
N
Neutral
21
Opening motor 1
22
Closing motor 1
25
Opening motor 2
26
Closing motor 2
+E
Encoder positive
41
Motor 1 encoder signal
45
Motor 2 encoder signal
-E
Encoder negative
18
Electrical lock negative
19
Electrical lock positive
11
Flashing light positive
0
Accessories negative
17
Gate open warning light positive
0
Accessories negative
1
Accessories positive
0
Accessories negative
+B
Emergency battery positive
-B
Emergency battery negative
52
Pedestrian (NO)
51
Step by step (NO)
62
Photocells when closing (NC)
63
Photocells (NC)
64
Sensitive edge (NC)
61
Stop (NC)
99
Common inputs
Trimmer functions:
Trimmer Description
Power of motor 1
MOT 1
(turn the trimmer clockwise to increase the power)
Power of motor 2
MOT 2
(turn the trimmer clockwise to increase the power)
Button functions:
Button Description
PROG
Button for programming the travel
MRX
Button for programming or deleting remote controls
51
Step-by-step command button
4
Rated data
120 to 230 Vac
24 Vdc 80W
24 Vdc 80W
12 Vac 15 VA
24 Vdc 10 W
24 Vdc 120 mA
24 Vdc 300 mA
EN
DIP-switch functions
DIP
Status
Description
OFF
Close immediately off
DIP 1
ON
Close immediately on
OFF
Automatic closing off
DIP 2
ON
Automatic closing on
2 steps: step-by-step (term. 51 and radio) with logic
OFF
in 2 steps (open - close - open)
DIP 3
Step-by-step command (term. 51 and radio) with
ON
logic in 4 steps (open - stop - close - stop - open -
stop)
OFF
Apartment block off
Apartment block on (while the gate is opening, you
cannot stop the movement with a radio command
or with inputs 51 (step-by-step) and 52 (pedestrian).
With automatic closing on (DIP-switch 2 = ON) and
DIP 4
ON
the gate open, an additional step-by-step command
(terminal 51 or radio command) renews the pause
time and if input 51 remains engaged the control
panel suspends the pause count until the input is
disengaged (for connecting any coils or a timer)
OFF
Slowdown distance at 10% of the travel
DIP 5
ON
Slowdown distance at 20% of the travel
OFF
Hammering for electrical lock off
DIP 6
Hammering for electrical lock on (required when
ON
using an electrical lock)
OFF
Status of gate closed at reset
Status of gate open at reset
When the power supply is restored, a step-by-step
DIP 7
ON
command causes closing and if automatic closing
is on (DIP-switch 2 = ON), closing occurs after the
pause time
OFF
Photo-test off
Photo-test on
DIP 8
At the start of each action, the control panel checks
ON
the operation of the photocells.
It requires specific wiring
OFF
Cycle speed high
DIP 9
ON
Cycle speed low
OFF
Double swing gate leaf (M1 and M2 on)
DIP 10
ON
Single swing gate leaf (
LED functions
LED
Status
Description
OFF
Mains power supply not present
PWR
ON
Mains power supply present
1 blink
Saving a new remote control
2 blinks
Saving a remote control already in memory
3 blinks
Deleting a remote control
MRX
4 blinks
Radio memory full
5 blinks
Savable remote control not in memory
10 blinks
Complete deletion of the radio memory
OFF
Step-by-step input (term. 51) not engaged
51
ON
Step-by-step input (term. 51) engaged
OFF
Pedestrian input (term. 52) not engaged
52
ON
Pedestrian input (term. 52) engaged
OFF
Stop contact (term. 61) open (engaged)
61
ON
Stop contact (term. 61) closed (not engaged)
OFF
Photocell engaged when closing (term. 62 open)
62
ON
Photocell not engaged when closing (term. 62
closed)
OFF
Photocell engaged when opening (term. 63 open)
63
ON
Photocell not engaged when opening (term. 63 closed)
OFF
Sensitive edge engaged (term. 64 open)
64
ON
Sensitive edge not engaged (term. 64 closed)