7)Whether the mechanical protective device is in good condition.
8)Whether the rotation part of the tool is flexible, light and free.
9)Whether the electrical protection device is good.
The application of tools must have full-time personnel for regular inspection:
1 )Check at least once a day.
2)The inspection cycle should be shortened correspondingly in areas where humidity is hot and temperature changes frequently, or
where conditions are hard.
3)Checked in time before the rainy season.
4)The periodic inspection items of the tool must also measure the insulation resistance of the tool. The insulation resistance shall not
be less than the value specified in Table 1.
Insulation resistance should be measured using 500V megabytes
Table 1
Measure par
Between
the
charged parts and the
cove
5)a qualified tool shall be pasted the "qualified" label at the appropriate part of the tool. The "qualified" logo should be clear, clear and
correct, and should include at least:
a)tool numbe
b)the name or mark of the uni
c)the name or mark of the inspector
d)valid date
Long term idle tools, insulation resistance must be measured before use. If the insulation resistance is less than the value speci-fied in
Table 1, the drying process must be carried out before before it is checked and qualified.
When the tools find insulation damage, failure of power line brokers, protective grounding wire(PE) falling off, plug and socket
opening or damage to safe mechanical damage, repair should be carried out immediately, and it shall not be used before repair.
The maintenance of the tool must be carried out by the maintenance unit approved by the original production unit.
The use unit and maintenance department may not modify the original design parameters of the tool arbitrarily, and shall not use
substitutes and parts which are not in conformity with the original specifications.
During maintenance, the insulation lining and bushing in the tool must not be arbitrarily removed or missed. The power supply line of the
tool must not be changed at will.