The system has been studied to motorize sectional doors.
To be applied onto balancing doors, a special fitting arm is required (cod. ACG8201T).
In any case, following conditions will have to be observed:
- the distance between the door highest point and the ceiling must be at least 40mm.
- it has to be possible to open and close the door by pulling and pushing horizontally its top edge.
- manual moves must be smooth and regular.
Figure 1 shows the dimensions, in mm
Figure 2 illustrates a typical installation.
Ref.
1
2
3
4
5
6
7
8
CAUTION: The mains connection must be made using a separate channel, independent of the control and safety equipment.
Drill 2 holes at the exact centre of the door, as shown in figure 3.
Provisionally mount the drive guide to the wall with two anchor bolts, as shown in figure 4.
The drive guide must be free to move towards the ceiling.
If the drive guide divided in 2 parts is used, it is necessary to assemble it by using a special joint.
The joint is provided inside one of the 2 parts of the drive guide and it is sufficient to align the drive guide and to slide the joint on the drive guide as shown
in picture number 6.
As shown in figure 5, fit the mounting plate to the drive guide at about 60 cm from the motor, then fold the two ceiling brackets (paying attention to the
distance between the drive guide and the wall) and secure them to the mounting plate.
Raise the drive guide as shown in figure 6 and secure the brackets to the ceiling (see figure 7).
The drive guide must be perfectly horizontal.
Secure the drive guide to the wall and the drive bracket to the top edge of the door.
There must be a gap of at least 10 mm between the top edge of the door and the drive guide.
Open the cover (figure 8) and remove the two bolts indicated in figure 9, then extract the lock plate (figure 10).
Fit the motor to the Rail de guidage (figure 11). Restore the lock plate and screw the two bolts in again (figure 12).
Bring the door in fully open position and fix the mechanical stop at 1 cm in distance as shown in picture number 16.
Block permanently the mechanical stop by drilling 2 holes on the drive guide and screwing the two 3,5 mm self-threading screws.
You can now make the electrical connection; use the cable already wired to the control unit (figure 13).
The system must be grounded (GND) as required by established regulations.
When the door is fully closed, the drive bracket must be at an angle of about 45° to the drive guide, see Figure 16.
If necessary, shorten the bracket and use the other mounting holes.
GENERAL INFORMATION
TYPICAL INSTALLATION
Code
Item
AA40826
CUBE 7
AA40827
CUBE 10
ACG8214
Drive guide
ACG8215
ACG8216
ACG8212
ACG9456 + 2 ACG9511 Set 2 batteries
AD00913
SET NO TOUCH
ACG6052
SUN 2CH
ACG7061
Blinker
INSTALLING THE AUTOMATION
DIMENSIONS
Description
700N automation for sectional and tilt-up doors
1000N automation for sectional and tilt-up doors
L = 3 m full
L = 3 m sectioned
L = 4 m full
L = 4 m sectioned
Allows movement of the door in case of blackout
Photocells without cables - helpful to prevent any
contact with door in closure.
Rubber profile
433MHz Remote control
Safety release
With 3W led lamp
IMPORTANT
19