speeds and decelerations (ramp down) used during its cycle.
N.B.: the auto close delay is set by the operator in a range of 0 ÷ 90 seconds.
The entire programming procedure is performed at low speed.
With Dip 2 OFF = auto close disabled. The open, close and stop commands are sent with the remote control or button.
If an error occurs during the teach-in procedure, or subsequent to a displacement of the mechanical opening stopper, repeat the procedure.
The new procedure should only be performed with door electrically completely closed.
With the door closed, hold down MEMO RX (P2) and press the desired transmitter button within 5 sec.; the courtesy lamp will flash to confirm memorization.
Repeat for each separate transmitter.
Up to 60 different codes can be stored in this way.
TO DELETE A REMOTE: Hold down MEMO RX (P2) until the courtesy light turns on, then press the transmitter button.
The courtesy light flashes 3 times to confirm the deletion. Now release the MEMO RX (P2) button.
TO DELETE ALL REMOTES: Hold down MEMO RX (P2) until the courtesy light goes out.
The courtesy light flashes 9 times to confirm that the memory has been deleted. Now release the MEMO RX (P2) button.
COURTESY LIGHT SIGNALS
no FLASH = transmitter to memorize.
1 FLASH = transmitter memorized.
2 FLASHES = a previously memorized transmitter is being re-memorized.
3 FLASHES = a transmitter has been deleted.
4 FLASHES = in delete mode, transmitter not memorized.
5 FLASHES = memory full.
9 FLASHES = all memorized codes deleted.
Tilt-up doors
CUBE can also be installed to tilt-up doors; in this case you must install the ACG8201T adapter to the door as shown in figure 17.
In order to join the bent arm of the CUBE to the straight arm provided with the accessory ACG8201T it is necessary to cut the bent drive as shown in pict.17
so join the 2 arms (the screws are not provided).
CAUTION: With the door open, the ACG8201T adapter will occupy 20 cm below the door.
Emergency battery kit
An emergency battery kit is available (code ACG9456 + 2 ACG9511) to allow the automation to work even during mains power failures.
Fit the batteries in their compartments and hook them up as shown in Figure 18.
TECHNICAL DATA
Power
Motor feed
Power draw
Standby power draw
Traction/thrust
Maximum stroke
Accessory power
Opening speed
Closing speed
Maximum load
Intermittency
Operating temperature
Protection rating
Noise level
Weight
MEMORIZING TRANSMITTERS
OPTIONAL ACCESSORIES
CUBE 7
115 ÷ 230 Vac 50/60 Hz
24 Vdc
1 A
1 W without accessories
3 W with accessories
700 N
2700 mm
24 Vdc - 0,5 A max
0,12 ÷ 0,20 m/s
0,12 ÷ 0,20 m/s
9 sqm
Intensive Use
-20 ÷ +50 °C
>60 dB
1.6 kg
21
CUBE 10
1,5 A
1000 N
12 sqm
IP 10
1.6 kg
G
B