Alarm Horn
Pressing the test/
silence switch or ac-
tivating the alarm
fl oat should turn on
the alarm horn. If the
horn does not sound, replace horn with same type.
Alarm Light
Pressing the test/silence switch or activating the alarm
fl oat should turn on the alarm light. If the light does
not activate, replace the control module.
Float Controls
Check the fl oats during their entire range of operation.
Clean, adjust, or replace damaged fl oats.
Checking the fl oat resistance - The fl oat resistance
can be measured to determine if the fl oat is operating
correctly or is defective. Use the following procedure
to measure the fl oat resistance.
WARNING: Disconnect incoming power to panel.
SJE-Rhombus
®
SJE-RHOMBUS
warrants to the original consumer that
this product shall be free of manufacturing defects for fi ve
years after the date of consumer purchase. During that time
period and subject to the conditions set forth below, SJE-
®
RHOMBUS
will repair or replace, for the original consumer,
any component which proves to be defective due to defective
materials or workmanship of
ELECTRICAL WIRING AND SERVICING OF THIS
PRODUCT MUST BE PERFORMED BY A LICENSED
ELECTRICIAN.
THIS WARRANTY DOES NOT APPLY: (A) to damage
due to lightning or conditions beyond the control of SJE-
RHOMBUS
®
; (B) to defects or malfunctions resulting from
failure to properly install, operate or maintain the unit in
accordance with printed instructions provided; (C) to failures
resulting from abuse, misuse, accident, or negligence; (D) to
units which are not installed in accordance with applicable
local codes, ordinances, or accepted trade practices, and (E)
to units repaired and/or modifi ed without prior authorization
from SJE-RHOMBUS
®
.
Products returned must be cleaned, sanitized, or decontaminated as necessary prior to shipment to ensure that employees
will not be exposed to health hazards in handling said material. All applicable laws and regulations shall apply.
4
Troubleshooting
Five-Year Limited Warranty
®
SJE-RHOMBUS
®
.
1. Isolate the fl oat by disconnecting one or both of the
fl oat leads from the fl oat terminals.
2. Place one ohmmeter lead on one of the fl oat wires,
and the other ohmmeter lead on the other fl oat wire.
3. Place the ohmmeter dial to read ohms and place
on the R X 1 scale. With the fl oat in the "off" posi-
tion, the scale should read infi nity (high resistance).
Replace the fl oat if you do not get this reading. With
the fl oat in the ON position, the scale should read
nearly zero (very low resistance). Replace the fl oat
if you do not get this reading.
NOTE: Readings may vary depending on the length
of wire and accuracy of the measuring device.
Fuses
Check the continuity of the fuse. With power OFF, pull
the fuse out of the fuse holder. With the ohmmeter on
the R X 1 scale, measure resistance. A reading of infi nity
indicates a blown fuse and must be replaced. Replace
fuse with same type, voltage and amp rating.
Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to
you. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation
or exclusion may not apply to you. This warranty gives you
specifi c legal rights, and you may also have other rights which
vary from state to state.
TO OBTAIN WARRANTY SERVICE: The consumer
shall assume all responsibility and expense for removal,
reinstallation, and freight. Any item to be repaired or replaced
under this warranty must be returned to SJE-RHOMBUS
or such place as designated by SJE-RHOMBUS
ANY IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS ARE LIMITED TO THE DURATION OF THIS
WRITTEN WARRANTY. SJE-RHOMBUS
IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES AS A RESULT OF
A BREACH OF THIS WRITTEN WARRANTY OR ANY
IMPLIED WARRANTY.
NOTICE!
®
,
®
.
®
SHALL NOT,