G
ELECTRIC CONNECTIONS
B
16 - COM
Common inputs (negative).
Input of pair of safety photocells; the interruption of the open door range keeps the automatic closure time paused until such range is resumed, whe reas in the
17 - FOTO RAL
closure phase, it reverses the movement.
N.C. safety, the opening of the contact (16-18) stops the movent of the doors and inhibits any order. The resetting of the contact and a subsequent "open" order
18 - STOP
makes the door open completely in slow motion; then it remains waiting for an OPEN order.
The automation will resume automatic operation with the previous parameters.
Input of pair of safety photocells; the interruption of the open door range keeps the automatic closure time paused until such range is resumed, whe reas in the
19 - FOTO
closure phase, it reverses the movement.
20 - R. INT
Internal side opening sensor; it sends an "open" order. In "closure" phase, it reverses the movement.
21 - R. EXT
External side opening sensor; it sends an "open" order. In "closure" phase, it reverses the movement.
N.O. input, if closed with input COM (22-16), it "opens" the automation keeping it in position until the contact itself is reopened. Set parameter "I" to 0 of the
22 - OPEN
selector-programmer (optional) in order to manage the open-close orders alternately; set parameter "I" from 1 to 9 according to the desired automatic closure time
(I1=1 min., I2=2 min., etc...).
23 - INT. I
There are terminals available for future implementations.
24 - INT. O
FIRE-FIGHTING
Connect the fire-fighting device to terminals COM (16) and OPEN (22). When the fire-fighting device is activated, it will open the door and will keep the door open.
POWER SUPPLY CONNECTION
Before connecting the power supply, make sure the data on the plate correspond to the
mains power supply.
Fit an omnipolar/disconnecting switch on the power supply network with contacts opening
distance of at least 3 mm.
Make sure there is a suitable circuit breaker and overcurrent protection device upstream
from the electrical system.
Make sure there are no sharp edges that may damage the supply cable.
CONTROLS AND ACCESSORIES POWER SUPPLY (Fig. 12)
ELECTRICAL CONNECTIONS TO CHOOSE THE COLORS OF LED BAR:
brown LED30 - white -28 = RED LIGHT
brown LED30 - yellow -28 = BLUE LIGHT
brown LED30 - green -28 = GREEN LIGHT
brown LED30 - yellow with white -28 = MAGENTA LIGHT
brown LED30 - green with yellow -28 = SAPPHIRE LIGHT
brown LED30 - white with yellow and green -28 = WHITE LIGHT
The connection to the mains power supply, in the automation external part, must be made
via an independent channel, separated from the connections to control and safety devices.
Led on - Night stop
brown connection
Leds always on
brown connection
34
ONE SLIDER 120 code SLI0001
ONE SLIDER 160 code SLI0002
LED
+
-
30
29
28
LED 30
12
+ 29