10. Light Kit Assembly (Optional). (cont.)
Replace lock washer and hex nut on threaded rod. Tighten
hex nut over lock washer so that the switch housing cap
fits securely on the light kit fitter. Make wire connections as
described below.
Connect WHITE wire from light kit fitter to WHITE wire
from switch housing. Connect BLACK wire from light kit
fitter to BLACK (or BLUE) wire from switch housing. Be
sure that molex connections snap together completely.
Align holes in switch housing cap with holes in switch
housing. Re-insert screws that were previously removed.
Securely tighten all 3 screws.
Install 2 medium base compact fluorescent 13 watt bulbs
(included).
Important: When replacing bulbs, please allow bulb(s) and
glass shade to cool down before touching them.
Remove finial from threaded rod at bottom of light kit fitter. Raise
glass shade and align threaded rod on light kit fitter with hole in
middle of glass shade; push up gently allowing threaded rod to
come through hole. Secure glass shade to light kit fitter with
finial provided.
Note: Do NOT overtighten finial as glass may crack or break.
11. Testing Your Fan.
It is recommended that you test fan before finalizing
installation. Restore power from circuit box and wall switch (if
applicable). Test fan speeds with the pull chain labeled FAN.
Start at the OFF position (no blade movement). First pull will
set the fan to HI. Second pull will set the fan to MEDIUM.
Third pull will set the fan to LOW. Fourth pull will re-set the
fan to OFF setting. If applicable, test light with the pull chain
labeled LIGHT. (Refer to diagram 1.) If fan and/or light do
(does) not function, please refer to "Troubleshooting" section
to solve any issues before contacting Customer Service.
Important: While it is necessary to lift the cover on the
reverse switch to operate the reverse switch, DO NOT remove
weatherporof cover from reverse switch.
Turn fan completely off before moving the reverse switch. Set
reverse switch to recirculate air depending on the season:
- LEFT position in summer (diagram 2)
- RIGHT position in winter (diagram 3)
A ceiling fan will allow you to raise your thermostat setting in
summer and lower your thermostat setting in winter without
feeling a difference in your comfort.
Important: Reverse switch must be set either completely LEFT
or completely RIGHT for fan to function. If the reverse switch is
set in the middle position (diagram 4), fan will not operate.
Attach pull chain extension(s) supplied or custom pull chain
extension(s) (sold separately) to the end(s) of the pull
chain(s).
hex nut
lock washer
bulb
Hg
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup
Requirements. In case of breakage, follow clean-up
procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010
reverse switch
with weather-
proof cover
light pull
chain extension
diagram 1
diagram 2
page 9
molex connections
switch housing
cap
light kit fitter
threaded rod
glass shade
finial
fan pull
chain extension
diagram 3
diagram 4