1. Install the Eccentric Shank
Slide one coupling nut and one flange onto each cold and hot
eccentric shank.
Measure and install the nipple. If the eccentric shank has female
threads, the nipples should extend 3/8" (1 cm) to 1/2" (1.3 cm)
from the front of the wall. If the eccentric shank has male threads,
the nipple should be flush with the front of the wall.
Thread one eccentric shank assembly onto each cold and hot
nipple. Ensure that each flange is snug against the finished wall.
Kohler Co.
Nipple
Flange
Coupling Nut
Eccentric
Shank
(Female
Thread)
Flange
Coupling Nut
Eccentric
Shank
(Male
Thread)