Checking For Leaks - Dyna-Glo DGA480BSN Manual De Instrucciones

Ocultar thumbs Ver también para DGA480BSN:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ASSEMBLY INSTRUCTIONS
In the connection process, make sure:
• The gas supply hose does not come in contact or remain in contact with the firebox.

CHECKING FOR LEAKS

After all connections are made, check all connections and fittings on the natural gas quick connector,
gas hose and manifold for leaks with a water and soap solution.
To prevent fire or explosion while testing for a leak:
• Always perform leak test prior to lighting the grill.
• Do not smoke while testing for a leak.
• Always perform leak tests outdoors in a well-ventilated area.
• Do not use any source of flame while testing for leaks.
• Do not use the grill until any and all leaks are corrected.
• If you are unable to correct a leak, close the manual gas shutoff valve and call a gas appliance
service agency.
PERFORM LEAK TEST
• Prepare leak test solution by combining 1 part liquid dish soap with 3 parts water.
Total solution required is approximately 2 - 3 ounces (70 - 90 ml).
Put leak test solution in a spray bottle.
• Ensure all control knobs are in the 'OFF' position.
• Connect the gas hose to the gas supply.
• Open the gas shutoff valve.
• Spray leak test solution on all gas carrying connections and fittings. Presence of bubbles at areas
of applied test solution indicates a gas leak. If leaks are detected or you smell or hear gas, shut off the
gas supply valve immediately and repair or replace the defective part. Do not use the grill until
all leaks are corrected.
Only use the hose assembly provided! If a replacement is necessary, please call our customer
service center. Do not use replacement parts that are not intended for this grill.
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.
WARNING
CAUTION
WARNING
14