4. Put the breast form into the bra cup. Ensure that the hose is connected correctly with the
breast form. Diagram 8 page 4
5. Bring the bra strap back into the correct position. Diagram 9 page 4
6. Now, adjust the breast form to your needs by pressing the pump ball (1). To drain the air,
press the black button on the drain valve (2) and lightly press the breast form against the
chest wall. Diagram 10 page 4
7. Please note: In order to insert or drain air, the cannula must be inserted completely into
the valve.
8. As soon as the correct volume is set, remove the cannula carefully from the valve. The air
remains in the air chamber. Diagram 11 page 4
9. Now the breast form has been adapted to your individual needs. Take it out of the bra
cup and put it into the bra's breast form pocket. Diagram 12 page 4.
General Care Instructions for Adapt Air Breast Forms
• When cleaning, ensure that no water enters the valve.
• Due to the valve, we do not recommend you wear Adapt Air when swimming.
• Changes in air pressure can lead to minimal, invisible changes in volume. Adjust the
volume with the pump if necessary.
• Use only the pump supplied with the breast form for any adjustments.
General Care Instructions for Pump
Clean the pump ball, the hose if necessary, and the drain valve with a mild soap solution.
Disinfectants which contain alcohol can damage the pump.
The proper function of the pump is guaranteed between -10°C and + 40°C, while the
maximum permissible temperature lies between -30°C and +100°C.
It can be disinfected by boiling.
In this case, separate the component parts from the pump ball and boil it in ample water for
a short time.
Pump Materials
Hollow body: Soft PVC, phthalate-free
Silicone hose: Silicone
PP tip: PP
Pressure drain valve: ABS