TABLE 3. TROUBLESHOOTING CHART
Belowinchartformarevarioussymptomsofa
malfunctioningsystem,possibledefectsthatwillcause
theresymptomsandsuggestedcorrectivemeasure.The
SYMPTOMS
Burnerlightsoffveryslow
Burnerflashback
(roaringnoiseduringoperationandceramic
gridsurfacewillbedark)
Ceramicgridorburnersootingup
(whenneworaftercleaning)
Pilotcannotbeignited
Pilotlightsbutgoesout
Pilotstayslitandmainburnerwillnotlight
Failuretoignite
15. FREQUENCY OF OPERATOR CHECKS
Intermittent Use
Appliancesthatareusedseasonallyshouldbecheckedbefore
shutdownandagainbeforethenextuse.
Dusty,wetorcorrosiveenvironment.Sincetheseenvironments
cancausethegascontroltodeterioratemorerapidly,thesystem
shouldbecheckedmoreoften.
The gas control should be replaced if:
a.Itdoesnotperformproperlyaftertroubleshooting.
b.Thegascontrolknobishardtoturn
392929_HSRR30-2017-WO-V9.indd 8
CAUSES
-Ifcolorstaysdull,Partiallyblockedburner
orifice
-Pilotoutofadjustment
-Lowgas
-Damageedburner
-Firstcheckfordamagedburnerorifice
- I fburnerorificeisnotdamagedthencheck
fordamagedmanifold
-Blockedpilotorifice
-Gasvalvenotincorrectposition
- P ilotgasflowadjustmentscrewmaybe
closed
-DefectiveSpark/FlameSensor
-Defectivecontrol
-Loosewireorimproperlywired
-Defectivecontrol
-Blockedburnerorifice
-Maingasoff
-Airinthegasline
-Loosewireconnections
-Dirtywireconnections
Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters
chartassumesthatthepropergaspressureisavailableto
theheaterandthatthelightingprocedureisasstatedon
theplateattachedtotheheater.
SOLUTIONS
Replace(BurnerOrifice)
Re-adjustpilot
Correctlinepressureorcallyourgassupplier
Replace
Replaceifdamaged
Replace
Cleanpilotorificeorreplace
Replace
Openandadjust
Replace
Replace
Tightenconnections,checkwiringdiagram
Replace
Cleanorificeorreplace
Openmanualvalves
Bleedgasline
Tightenwireconnections
Cleanterminalsandsecureterminals
HIGH ALTITUDE OPERATION
1. PleasecontactthefactoryforadetailedHighAltitude
ConversionKittosuityourspecificneed.
1.1Bepreparedtoanswerfactoryquestions
regarding:Typeoffuelfortheproposedappliance
conversion,gaspressureavailableatsite,andspecific
altitudeatsite.
2. "Theconversionshallbecarriedoutbya
manufacturer'sauthorizedrepresentative,
inaccordancewiththerequirementsofthe
manufacturer,provincialorterritorialauthorities
havingjurisdictionandinaccordancewiththeir
requirements."
3. HighAltitudeConversionKitswillincludehigh
altituderatingplatewithstampeddata,necessary
orificesorburnerasrequiredforspecificneedand
additionalinstallationinstructions.
4. InCanada,HeaterinstallationsatHighAltitudesshall
complywiththeapplicableconstructionprovisionsof
thecurrentstandardCAN1-2.17,gasfiredappliances
foruseathighaltitudes.