STEP 6:
ADJUST HEIGHT OF NEW FILL VALVE
A: TWIST FILL VALVE TO ADJUST HEIGHT
Top of fill valve cap should measure roughly 3"
above top of overflow pipe when installed.
NOTE:
Increasing height allows
more water to fill in the tank.
TWIST
LEFT
Fill Valve Cap
*Lever Hole
*
The top of the overflow pipe must be a minimum of 1" below tank lever hole.
8
HOLD
Do Not Move Lock Ring
TOP OF FILL VALVE
CAP
3"
TOP OF OVERFLOW PIPE
Overflow Pipe
STEP 7: INSTALL NEW FILL VALVE
A:
PUSH REFILL TUBE ONTO FILL
VALVE REFILL PORT
B:
INSERT FILL VALVE
Position refill tube to face flush valve
making sure fill valve parts do not
interfere with lever arm*.
Fill Valve
Refill Tube
Flush
Valve
Lever Arm
C:
ATTACH REFILL CLIP TO
OVERFLOW PIPE
Note: If refill tube is too long to
fit inside tank with lid closed,
remove refill tube from fill valve
refill port, cut tube and
reattach to port.
D:
INSTALL LOCKNUT
Screw locknut to the right
(counterclockwise) onto fill valve shank
(below tank).
**Hand-tighten only. DO NOT OVERTIGHTEN.
* Make sure the float cup does not touch the tank walls or tank lever and flush valve.
* * Overtightening may crack the fill valve or tank causing flooding.
TOP
DOWN
VIEW
Scissors
(Optional)
RIGHT
9