Descargar Imprimir esta página

METRO PROFESSIONAL GCV1100 Manual De Instrucciones página 14

Ocultar thumbs Ver también para GCV1100:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 69
Problem
Possible cause
2.1 Nearby heat
source hinders
cooling process
GB
2.2 Ventilation
insufficient
2.3 Door(s) not
closed
2.4 Damaged
seal(s)
2. Unsatisfactory
2.5 Air suction or
cooling
outlet blocked
2.6 Temperature
set too high
2.7 Compartment
too full
2.8 Contents not
properly pre-cooled
3.1 Appliance is not
levelled
3.2 Appliance
3. Noise
contacts obstacle
3.3 Shifting
compartment
content
Following phenomena are not troubles:
1. Murmur of water is heard when the appliance is
operating. It is a normal sound of the coolant circulating
in the system.
2. Condensation might be found on the outside of the
appliance, which is caused by high humidity. Follow the
cleaning advice described within these instructions.
Principle of refrigerating system
Solution
The principle of compression refrigeration consists
of "compression", "condensation", "throttling" and
2.1 Relocate
"vaporization".
appliance
2.2 Ensure
surrounding
clearance
2.3 Close door(s)
2.4 Check by a
A. Drying filter
specialist
B. Liquid
C. Capillary device
2.5 Re-arrange
D. Gas
compartment
E. Evaporator
content
F. Low pressure gas
G. Compressor
2.6 Regulate
H. High pressure and high temperature gas
the temperature
controller
Circuit diagram
2.7 Reduce
contents
2.8 Cool foodstuff
down before
placing them
into the cooling
compartment
3.1 Level the
appliance
3.2 Remove
obstacle
3.3 Re-arrange
compartment
content
I. Defrost probe
J. Thermostat probe
K. Digital temperature controller
L. Display panel
M. Power switch
N. Fan motor
O. Lamp
P. Overload protector
Q. Compressor
R. Thermistor (PTC)
- 13 -
A
B
G
H
I
K
M
N
C
D
F
J
L
P
Q
O
R
E

Publicidad

loading