SOSTITUZIONE BATTERIE
Non disperdere le batterie scariche nell'ambiente
n.2 batterie alcaline 1,5V, tipo AAA
1
DATI TECNICI
________________________________________________
- Temperatura operativa
- Frequenza radio
- Portata radio
- Alimentazione
- Dimensioni max.(B x L x H)
DESCRIPTION
______________________________________________
The RF button pads are used to control actuators of the RF SYSTEM series such as:
• 3A output modules,
• 16A output modules,
• motor control modules.
The button pads (1, 2, 3, 4 channels) are provided with a green signal LED (A) and
a key (B) for each channel (C).
Each channel can be associated to a different actuator.
The control functions, as described below, can be triggered by pressing the upper or
lower part of the key.
CONFIGURATION
________________________________________________
All that is required to make the association with an output module is to press the key
of the channel to be combined, after having set the output module in learn
configuration.
__________________________________
2
4
-5° +40°C
100 m in campo libero
a batteria, 2x1,5V alcaline tipo AAA
116x80x22 mm
ENGLISH
A
Green signal LED
B
Balanced key
C
Channel
OPERATION
The control functions possible from the button pads are determined by the selection
of the operating mode made on the associated actuator:
• in combination with a 3A or 16A output module configured for BISTABLE
operation, for example for normal control of lights: the light is switched on (ON) by
pressing the upper part of the key and switched off (OFF) by pressing the lower
part;
• in combination with a 3A or 16A output module configured for MONOSTABLE
operation, for example for controlling a bell, it is possible to use either the upper
or the lower part of the key: the charge is activated when it is pressed and
3
disactivated when it is released;
• in combination with a 3A or 16A output module configured for TIMED operation,
for example for managing staircase lights. It is possible to use either the upper or
lower part of the key: the lights are switched on (ON) when it is pressed; there is
no effect when it is released since the lights are switched off (OFF) automatically
when the time set on the actuator has elapsed;
• in combination with an output module for motor control, for example for
controlling roller blinds: the blind is raised by using the upper part of the key and
lowered by using the lower. The blind is stopped by using either the upper or
lower part of the key when it is in motion.
SIGNALS
____________________________________________________________
Transmission of a command
When any key is pressed, a blink of the corresponding green LED shows that a
command has been transmitted.
868 MHz
Batteries discharged
When any key is pressed, five blinks of the corresponding green LED show that the
batteries are becoming discharged. Transmission of the command is guaranteed in
any case. In this case, the batteries must be replaced as soon as possible.
If there are no light signals when a button is pressed, check that the batteries
are present and fitted correctly, and replace them if necessary.
INSTALLATION
WARNING
• Before installation ensure that the associated output modules receive the
commands correctly.
• During the installation stage respect the assembly sequence shown on the
UP
product (
).
Assembly with wall-plugs
1
Assembly with two-face adhesive tape
______________________________________________________
____________________________________________________
2
1
3
2
3