Connecting The Condensed Water Drain Of The Outdoor Unit; Electrical Installation - Tectro TS 1225 Manual De Instalación

Ocultar thumbs Ver también para TS 1225:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
WARNING
• Make sure the drain hose is situated at the bottom of the pipe bundle. Positioning the hose at
the top side can cause overflow of the condensed water container.
• Let the drain hose slope slightly over the entire length so the condensed water can be
evacuated smoothly.
9.2

Connecting the condensed water drain of the outdoor unit.

Place the sealing ring on the drainage pipe and position the drain connector in the hole on the bottom side
of the outside unit. Connect the drainage pipe to a drain hose (not supplied). In this way the condensed
water that is accumulated in the heating mode of the air conditioning can be drained. See Fig. 16.

10. ELECTRICAL INSTALLATION

Use a separate circuit for the air conditioner. Ensure the circuit is protected by a suitable fuse. See
table below.
The supply voltage must be within 95%~105% of the rated voltage, which is specified on the rating
label.
The supply circuit must be protected by an earth-leakage circuit breaker.
Ensure that the air conditioning is properly grounded.
Connect the cables according the wiring diagram. See Chapter 11.
All wiring has to comply with national and local electrical standards and regulations and has to be
connected by qualified technicians.
Picture 15
Picture 16
4
85

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cs 1225Ts 1232Cs 1232Ts 1248Cs 1248

Tabla de contenido