ELECTRICAL INSTALLATION

IMPORTANT: The electrical installation should be carried out by qualified personal only, according to
the regulations for electrical and mechanical safety in your country!
Please note the wire color code while connecting the mains cable:
 G: green/yellow color =
 N: blue color =
 L: brown color =
Important remarks:
 This projector must be earthed to comply with regulations!
 This projector can NOT be dimmed, do not connect on a dimmer pack!
When used/installed outside:
Make sure to use proper, waterproof connection boxes for the electrical connections! Our "LDP-
JUNCTION IP68" (order code: 5112) could be used for outdoor installation. (DMX-part not used)
OPERATING INSTRUCTIONS
 Once connected to the mains the projector starts working.
 Do not switch the projector on and off in short time intervals: this may damage the switching power supply.
 In the event of serious operating problems, stop using the projector and contact your dealer immediately.
 Important: Never look directly into the light source! Don't use the projector in the presence of persons
suffering from epilepsy.
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit and unplug the mains cable.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the heat sinks should be clean and not covered by any means.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
LDP-FLOOD10-WW
Mains Input:
Power consumption:
PF (power factor):
Luminous efficiency: 80lm/W
Initial luminous flux:
Beam Angle:
Color temperature:
Lamp:
IP-rating:
Size (mm):
Weight:
BRITEQ
®
Ground earth connection
Neutral
Live
AC 100 ~ 240V, 50/60Hz
10 Watt
>0.97
800lm
120°
3000K ~ 3300K
®
10W Bridgelux
LED cluster
IP65
115(L) x 86(H) x 105(D)
0,6kg
4/27