• Connect two separate ports to PUMProtector housing, by the
KlickTite quick connectors.
Straight connectors, ½" barb combined with
/
" pipe thread and ¾"
3
8
barb combined with ½" pipe thread are included in PUMProtector
kit. For use of port threads, cut the barb part of the connection unit.
Note! Other KlickTite port connectors are available as extra acces-
sories. See page 29.
When using solid pipework, always use an unclamped flexible hose
between solid pipework and pump/strainer unit. Recommended
hose length is 300 mm at both inlet and outlet side. This is to avoid
noise transfer from pump to hull and also to achieve a more gentle
operation of pump.
If the pump fails to prime, check that all joints are properly sealed.
Maintenance.
Inspect the strainer unit regularly for clogging. A clogged strainer
unit reduces performance and service of pump and pump system.
For cleaning, release the strainer unit by the two KlickTite quick
connections and bring it to a place where it is easy to clean. For
Universal Strainer you also need to loosen the two screws for at-
tachment, approx. 1 – 2 turns. Twist the cover off and take the
strainer screen out. Clean the screen, strainer housing and cover. A
dish wash detergent may be used.
9