Heath Zenith SL-5211 Manual Del Usuario página 2

Control de luz decorativo sensor de movimiento
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
.
❒ Before proceeding with the installation, TURN OFF
THE POWER TO THE LIGHTING CIRCUIT AT THE
CIRCUIT BREAKER OR FUSE BOX to avoid electrical
shock.
There are two types of decorative fixtures that the Instant Light
Control should be used with as shown here.
'A' shows a fixture with the wire going under the top cover. 'B'
shows a fixture with a open bottom and the wire going through
the bottom.
Drip
Loop
'A'
NOTE: The Drip Loop is neccessary to prevent rain from
running down the cord to the Sensor Module.
❒ Open the top of the light
fixture if it is necessary.
Remove the light bulb.
Screw in the lamp module
and replace the bulb.
'B'
Seal With Weather-
'B'
Proof Sealant
Drip Loop
❒ Plug the sensor cord into the switch module. The sensor
cord's plug is polarized for proper installation.
IMPORTANT: When installing the sensor, make sure the wire
comes out the bottom of the bracket and the wire has a drip
loop (as shown below) to help prevent water from entering the
sensor head.
Drip Loop
Mounting Sensor
❒ Mount the sensor approximately five feet above the ground.
Place the sensor below or beside the lighting fixture
so that the light from the decorative fixture will not hit
the sensor. Secure the sensor to the wall with the screws
provided. It may be necessary to tilt the sensor head up
slightly when mounting.
NOTE: Mounting the sensor above the light fixtures may
increase false triggering.
2
595-4238-07

Publicidad

Tabla de contenido
loading

Tabla de contenido