PICK & PLACE PEN MP 2260
The pick & place pen MP 2260 ref. 2260000 for
the placing of SMD is also delivered with the AM
6000.
The pen is connected to the plug VACUUM of the
station. Please find the connection plan on page 1.
A set of straight and bent needles as well as a
set of different sized suction cups is delivered
with the station:
- Set of suction cups
- Set of straight needles
- Set of bent needles
The suction cups can be adjusted to the needles
in order to make the placement of SMD of different
sizes on boards easier.
These accessories allows the adjustment to weight
and size of any type of component.
When you assemble the suction cup with the needle,
you should avoid the needle to stick out of the
lower part.
Component pick-up (Fig. A)
Place the needle tip on the component and block
the control orifice with the first finger of the other
hand so that the component may be held to the
.
needle by suction
Component placing (Fig. B)
Place the component in position on the printed
circuit. Remove your finger from the orifice
allowing air to enter whereby the component will
be released in the desired position
Ref.: 0940163
Ref. 0940163
Ref. 0901546
Ref. 0861660
.
CUPS
Ø A
COLOR
mm
2 x 4,3
BLACK
2 x 7
YELLOW
2 x 10
PINK
Faults and remedies
We list below the most frequent faults and the
possible remedies which you yourself may be
able to apply. In any case, the JBC technical
assistance service will attend to you if required.
Insufficient suction
The tubes have to be checked for possible air
escapes and the correct connection of the tubes
to their terminals must be observed. Check the
incoming air filter in the interior of the station and
replace it if dirty or obstructed.
Filter
Ref. 0861800
If in spite of this the suction is insufficient, the
self-contained vacuum pump should be checked.