Pipe Type:
ABS 32mm Waste Pipe,
(available in your local DIY store)
The actual size of pipe is approximately
36.3mm Outer Diameter x 31.8mm Inner Diameter
* Never joint the pipe, it must be a single piece.
40mm clearance
Pipe
lenght
40mm clearance

TECHNICAL INFORMATION

The Watchman Sonic Advanced is suitable for use in tanks for the
storage of diesel, water, fuel, kerosene, and gas oil types A2, C1, C2
and D as defined by BS 2869. Check with the manufacturer and/or
supplier before using with any other fluids.
CHANGING BATTERY
Please note opening the unit will potentially affect the
lifespan of the unit.
Under Warranty
Units under warranty SHOULD NOT BE OPENED. Warranty will
be void if unit is opened within the warranty period.
Out of Warranty Only
Though the lithium battery will have a very long service life, it
will eventually become exhausted and will need replacing. We
recommend using Varta CR2430.
• Remove transmitter from tank
• Take transmitter indoors, into a clean dry environment
• Using a cross point screwdriver, undo the four screws,
located under the main body of transmitter
• Remove the top cover
• Flip out battery
• Clip in new battery
• Re-fit cover
• Evenly tighten all four screws - do not over tighten
• Replace transmitter on the tank
• Clip in new battery
• Re-fit cover
• Evenly tighten all four screws - do not over tighten
• Replace transmitter on the tank
SPECIFICATIONS
Tank Depth
Minimum depth: 0.5m.
measurement:
Maximum depth: 3m.
Max
200m in normal "line of sight" conditions.
communication
The effective range of this product can be
distance
influenced by external sources that may reduce
the range of the transmitter or sensitivity of
the receiver.
Power supply:
Transmitter: 3-voltlithium cell.
Battery life:
Up to 3 years (dependant on tank height).
Wireless com:
433 MHz. FM transmission. EN 300-220.
Dimensions:
Transmitter: 70x93mm.
Max and min
Operating temp. Range -10º to +60 º C.
operating temp.
Operating humidity: 0-100%. Sealed airtight
(transmitter):
unit made from PP3317 UV stabilized.
Hole size:
32mm
for tank fitting:
2" BSP external thread adaptor
GUARANTEE
The Watchman Advanced has a warranty period of 1 year. For each
product accepted by Kingspan Water & Energy as warrantable,
Kingspan Water & Energy will rework or replace the product and
return to the customer at Kingspan Water & Energy expense. The
warranty becomes invalid if the sealed unit is opened (Part D).
Kingspan Water & Energy will not warrant products that have been:
• Used outside the functional and Water & Energy conditions for
which they were designed.
• Physically abused, incorrectly handled/ installed or damaged
in transit.
• Purchased over 1 year ago. (Proof of purchase will be required).
• Returned to Kingspan Water & Energy in a form other than in
which they were originally supplied.
• Subjects to "Act of God", e.g.: lightning strike, flood or any other
catastrophic event beyond Kingspan Water & Energy's control.
Any sensor product deemed damaged by the customer shall be
returned to Kingspan Water & Energy's facility at the customer's
expense. Kingspan Water & Energy shall not be liable for any costs in
relation to the returned products.
The purchase invoice and a description issue should be joined with
the faulty product. The product should be returned at your shop or
directly at the following address:
REGISTER GUARANTEE ONLINE:
kingspanwaterandenergy.com/warranty
Kingspan Water & Energy Ltd, 180 Gilford Road, Portadown,
Co. Armagh, Northern Ireland BT63 5LF.
Each faulty product must receive Kingspan Water & Energy's
After-Sale-Service approval before being returned.
Declaration: this apparatus is designed to: Not give rise to
physical injury or other harm due to contact. Not to produce
excessive surface temperatures, infrared, electromagnetic, ionising
radiation. To have no non-electrical dangers. When used in
accordance with these user and installation instructions.
Warning: If the equipment is likely to come in to contact with
aggressive substances, then it is the responsibility of the user to take
suitable precautions that prevent it from being adversely affected,
thus ensuring that the type of protection is not compromised.
Aggressive substances; - e.g. liquids or gases that may attack
metals, or solvents that may affect polymeric materials.
Supplied by Kingspan Water & Energy Ltd
180 Gilford Road, Portadown, Co. Armagh, Northern Ireland
Safety Information
Do not replace in a potentially explosive atmosphere
Periodically check that the unit is intact and securely fastened to
the tank.
Check with the manufacturer on the chemical compatibility prior
to use.
Do not attempt to repair this equipment. It must be returned to
the manufacturer for repair.
Warning! Electrostatic hazard! Clean only with damp cloth.
Use only VARTA CR2430 batteries.
Not suitable for pressurised containers.
Use on tanks vented to atmosphere.