Troubleshooting
Abnormal
E13
battery
temperature.
F1
Abnormal start.
Abnormal
F2
perimeter cable
signal.
The robot starts
F3
away from its
charging station.
Battery voltage
F4
too low.
The battery temperature
exceeds 65°C.
The robot mower started
more than a metre away
from or outside the
perimeter cable.
No perimeter cable signal.
When the robot mower is
switched off, it can only
restart on its charging
station.
The battery's voltage
is below 27 V. "F4" is
displayed until the voltage
is above 27 V, after been
charged.
23
Wait one (1) hour. Place
the robot mower less
than a metre away from
the perimeter cable and
restart it.
Place the robot mower
less than a metre away
from the perimeter
cable and restart it.
Check the perimeter
cable's condition. The
LED at the back of the
base must be steady
green. Place the robot
mower less than a
metre away from the
cable and restart it.
Place the robot mower
on its charging station.
When voltage is
above 27 V, the robot
mower leaves its
charging station and
automatically starts
mowing.