INTRODUCTION
Thank you for choosing this Scott product. Used and
maintained as described in this booklet it will provide
comfortable and efficient protection throughout a
long service life.
®
Phantom Vision
is a respirator system designed to
supply
filtered
air
environments.
Power-assisted respirator conforming to EN 12942.
Full face mask with an integral blower
Three mask sizes: small (S), medium (M) and
medium/large (M/L)
Mask-mounted filter
Waistbelt-mounted battery
Visor
meets
the
EN166,Grade B.
( Fig. 2) The blower draws air into the facemask
through the filter and directs the filtered air up to the
middle of the visor (the flow of air keeps the visor
clear of misting). Exhaled air exits through the
exhalation valve.
( Fig. 5) Wearers are able to decontaminate and
shower after work, whilst still wearing the respirator.
+ PV 251
Minimum air
+ PF 251/2 160 L/min
flow rate
Warning
A sound signal indicates that
buzzer
battery voltage is below optimum
level.
Battery
Li-ion rechargeable.
Operation time 8 hours.
Expected life-span min. 500
recharge cycles.
Charger
LED indicator
Weight
Mask+blower
Battery
Material
Visor
Coated polycarbonate
Facepiece
Silicone elastomer
Inner mask
Thermoplastic elastomer
Harness
EPDM
Operation
-10°C...+50°C, RH max. 95 %
Storage
-10ºC...+30ºC, RH max.75 %
Clean and dry environment,
protected from direct sunlight and
heat.
5 years
Service life
1 year
5 years
Shelf life
1 year
 See page 9
Warranty
for
use
in
dangerous
impact requirements
160 L/min
650 g
480 g
Faceseal
Inner mask
Valve flap
O-ring
Components
Battery
12
MARKINGS
SCOTT
EN12942
Protection factor
of
Nominal
Assigned
Date of manufacture
Blower device
Battery
-10 C
See Instructions for Use!
Recommended storage conditions (temperature
and humidity).
Manufacturer
Standard – power-assisted
respirator
Notified body: BSI, Kitemark
Court, Davy Avenue, Knowhill,
Milton
Keynes,
MK5
England
EC certificate: IFA, DE-53754
Sankt Augustin, Germany
AS/NZS 1716:2012
SAI Global Lic. SMK 1214
2000 (EN 12942)
Refer to local guidelines.
UK  It is advisable that
respirators of this class are not
used
in
contaminant
centrations
exceeding
Occupational Exposure Limit.
Mask
08
Year (2008)
Month (June)
Exhalation valve flap
8
year (2008)
dot
quarter of year
(Oct-Dec)
Head harness
08
year (2008)
dot
quarter of year
(Jan-Mar)
Reverse, see the four first digits
(month, year)
Reverse, see the tag (year)
+30 C
< 75 %
Disposal (WEEE):
 Blower, battery and cable
assembly
 See page 10
8PP,