4.3.15. User interface energy saving mode
By default, the screen power saving mode is activated and an appliance which is unused goes into standby: an
animated production indicator is displayed and the measured values are not visible. To deactivate this mode:
• From the Configuration/D15 ECO mode, press
• Press
to switch to "ON".
• Press
to confirm.
4.3.16. "Bio": "Bio pool" mode for natural pools
The "Bio" mode is used to modify the pH and ORP setpoints and the related high and low alarms (see the values in the
table below) so they are best suited to natural pools.
pH
ORP (mV)
By default, this mode is disabled; to activate it:
• From the Configuration/bio mode, press
• Press
to activate it ("ON").
• Press
to confirm.
4.3.17. Calibrating the temperature
• From the home screen, press
to enter the Calibration mode. The screen displays
• Press
• Press
to select this mode. The value flashes.
• Press
or
to change the value.
• Press
to confirm.
Press
at this step to switch between a temperature display in degrees Celsius (°C) and degrees Fahrenheit
(°F).
4.3.18. Calibrating the salt concentration
• From the home screen, press twice on
• Press
to enter Calibration mode. The screen displays
• Press
to select this mode. The value flashes.
• Press
or
to change the value.
• Press
to confirm.
31
« Bio pool »
mode
OFF (default)
7.0
ON
6.5
OFF (default)
600
ON
300
: "OFF" flashes.
to access the temperature values (*).
to access the salinity values.
: "OFF" flashes.
Threshold
7.8
8.5
850
850
("Standard").
("Standard").
Alarm
High (HI)
Low (LO)
> 8.5
< 6.5
> 9.0
< 6.0
> 855
< 600
> 855
< 300