Seal any unused connectors with a plug.
•
Once the appliance has been installed, check for
leaks at the connection points.
•
Hot water connection: the water temperature must
not exceed 60°C.
•
The water inlet pressure must be between 150 kPa
and 300 kPa. Use a pressure reducer if the inlet
pressure is above the maximum permitted level.
•
The appliance is intended to be permanently
connected to the mains water supply and not via
disconnectable fittings.
20
Instructions for installation
CONNECTION TO THE WATER DRAIN
The water drainage system must be provided using
materials resistant to temperatures of 100 °C.
The bottom of the appliance must not be subjected
to steam produced by drainage of hot water. Install a
siphoned floor drain with grating below the water drain
cock of Boiling pans and in front of Bratt pans.
13. COMMISSIONING
See Chapter " INSTRUCTIONS FOR MAINTENANCE".