Deep Combustion Chamber Cleaning; Storage And Disposal; Downtime (End Of Season); Disposal - Ravelli Alba Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 114
Remove the side tiles.
2b
Refractory tiles are fragile; be careful when removing them.
Note: The operation must be carried out when the stove is cold.

Deep combustion chamber cleaning

! IMPORTANT
To clean the combustion chamber, proceed as follows:
1
Take out the fire grate.
2
Take out the rotating grille.
3
Take out the refractory tiles.
4
Remove the residues from the combustion chamber with a suitable ash vacuum, ensuring that the ash is
completely extinguished.

STORAGE AND DISPOSAL

Downtime (end of season)

At the end of every season we recommend vacuuming out any ash and dust that may still be inside.

Disposal

Demolition and disposal of the stove is under the exclusive liability and responsibility of the owner who must do so in accordance with
the laws in force in the country of installation pertaining to safety, respect and protection of the environment.
At the end of its service life, the product must not be disposed of as household waste. It can be taken to designated separate waste
collection centres run by local administrations or to dealers who offer this service.
Disposing of the product as sorted waste avoids any negative consequences on the environment and health deriving from unsuitable
disposal and it recovers the materials that the stove is composed of in order to save considerable energy and resources.

TROUBLESHOOTING

The stove does not work

closely follow the directions in the dedicated chapter of this manual.
use seasoned wood with a low humidity content;
make sure that the air intake duct is not obstructed;
make sure that the smoke evacuation system is clean and not obstructed;
make sure the chimney is sized for the stove power;
make sure that the air intake in the room is clear of any obstructions and that there are no other combustion appliances or
extraction hoods that create a vacuum in the room;

Difficult lighting

closely follow the directions in the dedicated chapter of this manual;
open the primary air lever all the way;
not enough wood has been loaded for lighting;
use seasoned wood with a low humidity content;
make sure that the air intake duct is not obstructed;
make sure that the smoke evacuation system is clean and not obstructed;
make sure the chimney is sized for the stove power.
Use and maintenance manual Alba- Alba steel- Lia- Lia steel
This operation must be carried out by a Ravelli Assistance Centre.
Schedule this type of cleaning with the Ravelli Assistance Centre.
Remove the top tile and tile.