Attach The Counterweights - Kohler K-1914 Guia De Instalacion

Ocultar thumbs Ver también para K-1914:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Shims
Counterweight
Guide
Add shims that are 1/2"
(1.3 cm) to 1" (2.5 cm)
(total height).
Position the counterweight
on the shims.

14. Attach the Counterweights

All Installations
CAUTION: Risk of crushing or pinching. When installing the pulley cable, use the supplied tool.
The tool is designed to eliminate the risk of extremities being crushed or pinched between the cable
and pulleys while supporting the counterweights.
IMPORTANT! The door must be in the raised position while these steps are performed. Support the door
with a 2x4 or have the second installer hold it in place until the counterweights are attached.
Position extra protective material on the drip tray under the counterweight guides.
Position 1/2" (1.3 cm) to 1" (2.5 cm) high shims inside each of the counterweight guides.
On the drain side of the bath, carefully position a counterweight on shims aligned with the
counterweight guide.
On the side of the bath opposite the drain, carefully position the counterweight on the shims or the
board, aligned with the counterweight guide.
On each side, carefully run the pulley cable directly to the counterweights, making sure it does not
interfere with the limit switch wires and door power cable.
Attach the cables to the counterweights.
Use the provided tool to position each pulley cable over both pulleys.
On the drain side of the bath, remove the support shims and carefully lower the counterweights.
On the side of the bath opposite the drain, remove the support shims and carefully lower the
counterweights.
Check to make sure the counterweights do not come in contact with the drip tray.
Kohler Co.
Tool
Board
Counterweight
Route the cable over
the pulleys.
25
Attach the counterweight .
Pulley
Tool
Cable
1128535-2-B

Publicidad

Tabla de contenido
loading

Tabla de contenido